PurposeTo assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG) to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained.MethodsThis cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH) three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR), a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT) and falling rate (FR) were also recorded.ResultsArtifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients ≥ 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001). FR (r = 0.747, p<0.001) and BOT (r = -0.714, p<0.001) most strongly correlated with age.ConclusionsLSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion.
We present imaging of corneal pathologies using optical coherence tomography (OCT) with high resolution. To this end, an ultrahigh-resolution spectral domain OCT (UHR-OCT) system based on a broad bandwidth Ti:sapphire laser is employed. With a central wavelength of 800 nm, the imaging device allows to acquire OCT data at the central, paracentral and peripheral cornea as well as the limbal region with 1.2 µm x 20 µm (axial x lateral) resolution at a rate of 140 000 A-scans/s. Structures of the anterior segment of the eye, not accessible with commercial OCT systems, are visualized. These include corneal nerves, limbal palisades of Vogt as well as several corneal pathologies. Cases such as keratoconus and Fuchs's endothelial dystrophy as well as infectious changes caused by diseases like Acanthamoeba keratitis and scarring after herpetic keratitis are presented. We also demonstrate the applicability of our system to visualize epithelial erosion and intracorneal foreign body after corneal trauma as well as chemical burns. Finally, results after Descemet's membrane endothelial keratoplasty (DMEK) are imaged. These clinical cases show the potential of UHR-OCT to help in clinical decision-making and follow-up. Our results and experience indicate that UHR-OCT of the cornea is a promising technique for the use in clinical practice, but can also help to gain novel insight in the physiology and pathophysiology of the human cornea.
Adequate function of the retina is dependent on proper oxygen supply. In humans, the inner retina is oxygenated via the retinal circulation. We present a method to calculate total retinal oxygen extraction based on measurement of total retinal blood flow using dual-beam bidirectional Doppler optical coherence tomography and measurement of oxygen saturation by spectrophotometry. These measurements were done on 8 healthy subjects while breathing ambient room air and 100% oxygen. Total retinal blood flow was 44.3 ± 9.0 μl/min during baseline and decreased to 18.7 ± 4.2 μl/min during 100% oxygen breathing (P < 0.001) resulting in a pronounced decrease in retinal oxygen extraction from 2.33 ± 0.51 μl(O2)/min to 0.88 ± 0.14 μl(O2)/min during breathing of 100% oxygen. The method presented in this paper may have significant potential to study oxygen metabolism in hypoxic retinal diseases such as diabetic retinopathy.
Aims/hypothesisThe aim of this study was to compare retinal oxygen extraction in individuals with diabetes with no or mild non-proliferative diabetic retinopathy and healthy age- and sex-matched volunteers.MethodsA total of 24 participants with type 1 diabetes and 24 healthy age- and sex-matched volunteers were included in this cross-sectional study. Retinal oxygen extraction was measured by combining total retinal blood flow measurements using a custom-built bi-directional Doppler optical coherence tomography system with measurements of oxygen saturation using spectroscopic reflectometry. Based on previously published mathematical modelling, the oxygen content in retinal vessels and total retinal oxygen extraction were calculated.ResultsTotal retinal blood flow was higher in diabetic participants (46.4 ± 7.4 μl/min) than in healthy volunteers (40.4 ± 5.3 μl/min, p = 0.002 between groups). Oxygen content in retinal arteries was comparable between the two groups, but oxygen content in retinal veins was higher in participants with diabetes (0.15 ± 0.02 ml O2/ml) compared with healthy control participants (0.13 ± 0.02 ml O2/ml, p < 0.001). As such, the arteriovenous oxygen difference and total retinal oxygen extraction were reduced in participants with diabetes compared with healthy volunteers (total retinal oxygen extraction 1.40 ± 0.44 vs 1.70 ± 0.47 μl O2/min, respectively, p = 0.03).Conclusions/interpretationOur data indicate early retinal hypoxia in individuals with type 1 diabetes with no or mild diabetic retinopathy as compared with healthy control individuals. Further studies are required to fully understand the potential of the technique in risk stratification and treatment monitoring.Trial registration: ClinicalTrials.gov NCT01843114.
Measurements of RFV were successfully obtainable, reproducible, and not influenced by pharmacological pupil dilation. Nevertheless, our data revealed flaws in the LSFG method of measuring retinal perfusion in Caucasians. Adjustment to the technique is required to address apparent issues with RFV, especially saturation effects with higher arterial flow rates. The present dataset may provide a valuable tool to do so. (Clinicaltrials.gov number NCT02582411).
PURPOSE. To investigate the age-dependence of total retinal blood flow and total retinal oxygen extraction in healthy subjects and determine their possible correlations with structural optical coherence tomography (OCT) parameters. METHODS. This observational cross-sectional study consisted of 68 healthy subjects (mean 6 SD age, 45.6 6 16.3 years; 47% female). Total retinal oxygen extraction was calculated based on measurement of total retinal blood flow using bi-directional Doppler OCT and measurement of oxygen saturation using spectroscopic reflectometry. Retinal nerve fiber layer thickness was measured using OCT, and the total number of retinal ganglion cells was estimated based on a previous published model. Correlation of these parameters with age was studied and the association between structural OCT parameters and hemodynamic vascular parameters was calculated. RESULTS. Both structural and vascular parameters showed a significant decline with increasing age. The correlation coefficients were between r ¼ À0.25 and r ¼ À0.41. Furthermore, structural and vascular parameters were significantly correlated with each other. The strongest association was found between the level of total retinal oxygen extraction and the number of retinal ganglion cells (r ¼ 0.75, P < 0.001). CONCLUSIONS. We showed that there was an age-related decline of retinal oxygen extraction. Levels of retinal oxygen extraction are correlated to retinal nerve fiber layer thickness and number of retinal ganglion cells. Our data partially explain the wide inter-individual variability in retinal blood flow values in healthy subjects. Longitudinal studies are required to study the time course of vascular and neuronal loss in humans.
METHODS. In six healthy subjects, TRBF was measured before and during stimulation with diffuse luminance flicker. Blood flow velocities in retinal vessels were measured via dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT), retinal vessel diameters were assessed based on FD-OCT phase data. This allowed for the calculation of TRBF before and during visual stimulation. Additionally, a mathematical flow model for the retinal vasculature was adapted to study the implications of diameter variations on retinal perfusion. Measured and simulated perfusion was compared to draw conclusions on the diameter variations in different layers of the vascular tree.RESULTS. The measured mean baseline flow was 36.4 6 6.5 ll/min while the mean flow during flicker stimulation was 53.4% 6 8.3 ll/min. The individual increase in TRBF during flicker stimulation ranged between 34% and 66%. The average increase in TRBF over all measured subjects was 47.6% 6 12.6%.CONCLUSIONS. Dual-beam bidirectional Doppler FD-OCT allowed quantifying NC in the human retina in vivo and may be a promising method for monitoring alterations in NC caused by various pathologies. The comparison of the measured data with the results obtained in the simulated vasculature indicates that the vasodilation induced by NC is more pronounced in smaller vessels.
The present analysis indicates that retinal arterial and venous responses to stimulation with diffuse luminance flicker depend on the way the stimulation is delivered through the fundus camera. In addition, the flicker response varied with vessel size, that is, the smaller the vessel width, the larger the flicker response. Finally, our data indicate that, even within the normal range, higher cholesterol serum levels are associated with lower hyperemic flicker responses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.