The Hong Kong Environmental Protection Department has recently launched a set of guidance notes on indoor air quality (IAQ) management for offices and public places. An IAQ Certification Programme will be conducted on a self-regulatory basis that is intended to divide IAQ in mechanically ventilated buildings into three classes. Due to the large number of buildings in Hong Kong and the associated cost implications, a simplified, operationally feasible and scientifically sound assessment has been developed. Twenty-five government buildings covering eight different types of premises were examined in a trial-run programme to verify the validity of the proposed methodology. Among these 25 premises, only 1 (4%) achieved level 1 while 11 (44%) achieved the level 2 objective. The remaining 13 premises (52%) met the level 3 objective. High concentrations of volatile organic compounds and carbon dioxide were found to be the dominating parameters that made a building unable to meet class level 2. This measurement study has also illustrated the very different nature of IAQ found in different types of buildings where the pattern of air conditioning operation and indoor air pollutant sources can influence it substantially.
The Hong Kong Environmental Protection Department has recently launched a set of guidance notes on indoor air quality (IAQ) management for offices and public places. An IAQ Certification Programme will be conducted on a self-regulatory basis that is intended to divide IAQ in mechanically ventilated buildings into three classes. Due to the large number of buildings in Hong Kong and the associated cost implications, a simplified, operationally feasible and scientifically sound assessment has been developed. Twenty-five government buildings covering eight different types of premises were examined in a trial-run programme to verify the validity of the proposed methodology. Among these 25 premises, only 1 (4%) achieved level 1 while 11 (44%) achieved the level 2 objective. The remaining 13 premises (52%) met the level 3 objective. High concentrations of volatile organic compounds and carbon dioxide were found to be the dominating parameters that made a building unable to meet class level 2. This measurement study has also illustrated the very different nature of IAQ found in different types of buildings where the pattern of air conditioning operation and indoor air pollutant sources can influence it substantially.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.