Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as controls. Elevated serum RAST values (greater than 2.0) were more common in reactors (63%) than in controls (11%, p less than 0.001). In a second study, RAST assays were performed using human serum albumin conjugated to ETO (HSA-ETO) as antigen and also using a concentrate of fluid used to rinse ETO-sterilized dialyzers ("dialyzer extract") as antigen. The RAST ratios obtained with HSA-ETO were similar to those obtained using the dialyzer extract (rank order correlation coefficient = 0.829, p less than 0.001). In a third study, RAST inhibition was demonstrated both by HSA-ETO and dialyzer extract. Our results, extending previously published reports, suggest that hypersensitivity to ETO might play an important role in hemodialysis-associated hypersensitivity-type reactions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.