ObjectiveFaecal immunochemical tests (FIT) are replacing guaiac faecal occult blood tests (FOBT) in colorectal cancer (CRC) screening. Data from the first year of FIT screening were compared with those from FOBT screening and assumptions based on a pilot evaluation of FIT.DesignData on uptake, positivity, positive predictive value (PPV) for CRC and higher-risk adenoma from participants in the first year of the FIT-based Scottish Bowel Screening Programme (n=919 665), with a threshold of 80 µg Hb/g faeces, were compared with those from the penultimate year of the FOBT-based programme (n=862 165) and those from the FIT evaluation (n=66 225).ResultsOverall, uptake of FIT was 63.9% compared with 56.4% for FOBT. Positivity was 3.1% and 2.2% with FIT and FOBT; increases were seen in both sexes, and across age range and deprivation. More CRC and adenomas were detected by FIT, but the PPV for CRC was less (5.2% with FIT and 6.4% with FOBT). However, for higher-risk adenoma, PPV was greater with FIT (24.3% with FIT and 19.3% with FOBT). In the previous FIT evaluation, uptake was 58.5% with FIT compared with 54.0% with FOBT; positivity was 2.5% with FIT and 2.0% with FOBT.ConclusionTransition to FIT from FOBT produced higher uptake and positivity with lower PPV for CRC and higher PPV for adenoma. The FIT pilot evaluation underestimated uptake and positivity. Introducing FIT at the same threshold as the evaluation caused a 67.2% increase in colonoscopy demand instead of a predicted 10%.
ObjectivesFaecal immunochemical tests for haemoglobin (FIT) are becoming widely used in colorectal cancer (CRC) screening and assessment of symptomatic patients. Faecal haemoglobin concentration (f-Hb) thresholds are used to guide subsequent investigation. We established the distributions of f-Hb in a large screening population by sex, age, deprivation and geography.MethodsSingle estimates of f-Hb were documented for all individuals participating in the first 18 months of the Scottish Bowel Screening Programme (SBoSP). The distributions of f-Hb were generated for all participants, all men and women, and men and women by age quintile and deprivation quintile. Distributions were also generated by geographical region for all participants, men and women, and by deprivation. Comparisons of f-Hb distributions with those found in a pilot evaluation of FIT and three other countries were performed.Resultsf-Hb was documented for 887,248 screening participants, 422,385 men and 464,863 women. f-Hb varied by sex, age, deprivation quintile and geographical region. The f-Hb distributions by sex and age differed between the SBoSP and the pilot evaluation and the three other countries.Conclusionsf-Hb is higher in men than in women and increases with age and deprivation in both sexes. f-Hb also varies by geographical region, independently of deprivation, and by country. The f-Hb distribution estimated by pilot evaluation may not represent the population distribution. Decision limits have advantages over reference intervals. Use of partitioned f-Hb thresholds for further investigation, based on the data generated, has advantages and disadvantages, as do risk scores based on a spectrum of influencing variables.
Migraine headache is a common, chronic, debilitating disease with a complex etiology. Current therapy for migraine headache comprises either treatments targeting acute migraine pain or prophylactic therapy aimed at increasing the length of time between migraine episodes. Recent evidence suggests that calcium gene-related peptide (CGRP) is a critical component in the pathogenesis of migraines. Fremanezumab, a monoclonal antibody against CGRP, was recently approved by the Food and
Screening is an important component of cancer control internationally. In Scotland, the National Health Service Scotland provides screening programmes for cervical, bowel and breast cancers. The COVID-19 pandemic resulted in the suspension of these programmes in March 2020. We describe the integrated approach to managing the impact of the pandemic on cancer screening programmes in Scotland throughout 2020. We outline the policy context and decision-making process leading to suspension, and the criteria and framework informing the subsequent, staggered, restart in subsequent months. The decision to suspend screening services in order to protect screening invitees and staff, and manage NHS capacity, was made after review of numbers of screening participants likely to be affected, and the potential number of delayed cancer diagnoses. Restart principles and a detailed route map plan were developed for each programme, seeking to ensure broad consistency of approach across the programmes and nationally. Early data indicates bowel, breast and cervical screening participation has increased since restart. Primary care has had to adapt to new infection prevention control measures for delivery of cervical screening. Cancer charities provided cancer intelligence and policy briefs to national bodies and Scottish Government, as well as supporting the public, patients and screening invitees through information and awareness campaigns. Emerging from the pandemic, there is recognition of the need and the opportunity to transform and renew both cancer and screening services in Scotland, and in particular to address long-standing workforce capacity problems through innovation and investment, and to continue to prioritise addressing health inequalities.
Multimorbidity is the major cause of ill-health and premature death in developed countries. The ability to identify individuals at risk of developing chronic disease, particularly multimorbidity, reliably, and simply, and to identify undiagnosed disorders, is vital to reducing the global burden of disease. This narrative review, the first of recent studies, demonstrates that raised faecal haemoglobin concentration (f-Hb) is associated with increased all-cause and cause-specific mortality and with longer-term conditions including diabetes, hypertension, cardiovascular disease, and psoriasis, and with probable intake of particulate matter. We and others have hypothesized that elevated f-Hb (measured using a faecal immunochemical test) has considerable potential to identify individuals at risk of, or who already have, early stage, undiagnosed chronic disease. If f-Hb does prove to be an effective biomarker for chronic disease and multimorbidity, individuals with detectable f-Hb, but without an obvious source of gastrointestinal blood loss, could benefit from further assessment and early intervention. To test this hypothesis rigorously, longitudinal data-linkage methodology is required linking colorectal cancer screening data, and data on patients presenting with lower gastrointestinal symptoms, with routinely collected health information.
Objective There is evidence that colorectal cancer screening using faecal haemoglobin is less effective in women than men. The faecal haemoglobin concentrations were therefore examined in women and men with screen-detected colorectal cancer. Setting Scottish Bowel Screening Programme, following the introduction of a faecal immunochemical test from November 2017, to March 2020. Methods Data were collated on faecal haemoglobin concentrations, pathological stage and anatomical site of the main lesion in participants who had colorectal cancer detected. The data in women and men were compared. Results For the faecal haemoglobin concentrations studied (>80 µg Hb/g faeces), the distributions indicated lower concentrations in women. Marked differences were found between women and men diagnosed with colorectal cancer. The median faecal haemoglobin concentration for women ( n = 720) was 408 µg Hb/g faeces compared to 473 µg Hb/g faeces for men ( n = 959) ( p = 0.004) and 50.6% of the results were >400 µg Hb/g faeces in women; in men, this was 57.8%. The difference in faecal haemoglobin concentrations in women and men became less statistically significant as stage advanced from stages I–IV. For right-sided, left-sided and rectal colorectal cancer, a similar gender difference persisted in all sites. Differences in faecal haemoglobin between the genders were significant for left-sided cancers and stage I and approached significance for rectal cancers and stage II, but all sites and stages showed lower median faecal haemoglobin concentrations for women. Conclusions To minimise gender inequalities, faecal immunochemical test-based colorectal cancer screening programmes should evaluate a strategy of using different faecal haemoglobin concentration thresholds in women and men.
Currently, women are disadvantaged compared to men in colorectal cancer (CRC) screening, particularly in programmes that use faecal immunochemical tests for haemoglobin (FIT) followed by colonoscopy. Although there is no single cause for all the known disadvantages, many can be attributed to the ubiquitous finding that women have lower faecal haemoglobin concentrations (f-Hb) than men; there are many plausible reasons for this. Generally, a single f-Hb threshold is used in CRC screening programmes, leading to lower positivity for women than men, which causes poorer outcomes for women, including lower CRC detection rate, higher interval cancer (IC) proportion, and higher CRC mortality. Many of the now widely advocated risk scoring strategies do include factors taking account of sex, but these have not been extensively piloted or introduced. Using different f-Hb thresholds for the sexes seems advantageous, but there are difficulties, including deciding which characteristic should be selected to achieve equivalency, for example, positivity, IC proportions, or specificity. Moreover, additional colonoscopy resources, often constrained, would be required. Governments and their agencies should be encouraged to prioritise the allocation of resources to put simple strategies into practice, such as different f-Hb thresholds to create equal positivity in both sexes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.