A 785 nm laser dispersive Raman system was installed in a hazardous chemical production plant to monitor two reactors, a still, and a holding tank with measurement directly through sight glasses. Compositional information for several raw materials, intermediates, and products was obtained using partial least squares (PLS) calibrations. Discriminate analysis was used to exclude extremely poor spectra while including usable ones. Derivative/standard normal variate (SNV) treatment was found to be effective for correcting for background fluorescence and for large differences in spectral intensity. Final regression equations incorporated temperature fluctuations, occasional fluorescence, some sunlight effects, large intensity variations, and large compositional changes. Various installation problems were solved via data treatment or mechanical changes. The Raman system provides information for control of the process, resulting in cost savings and improved safety.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.