Background-Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a condition associated with the risk of sudden death (SD). Methods and Results-We conducted a multicenter study of the impact of the implantable cardioverter-defibrillator (ICD) for prevention of SD in 132 patients (93 males and 39 females, age 40Ϯ15 years) with ARVC/D. Implant indications were a history of cardiac arrest in 13 patients (10%), sustained ventricular tachycardia in 82 (62%), syncope in 21 (16%), and other in 16 (12%). During a mean follow-up of 39Ϯ25 months, 64 patients (48%) had appropriate ICD interventions, 21 (16%) had inappropriate interventions, and 19 (14%) had ICD-related complications. Fifty-three (83%) of the 64 patients with appropriate interventions received antiarrhythmic drug therapy at the time of first ICD discharge. Programmed ventricular stimulation was of limited value in identifying patients at risk of tachyarrhythmias during the follow-up (positive predictive value 49%, negative predictive value 54%). Four patients (3%) died, and 32 (24%) experienced ventricular fibrillation/flutter that in all likelihood would have been fatal in the absence of the device. At 36 months, the actual patient survival rate was 96% compared with the ventricular fibrillation/flutter-free survival rate of 72% (PϽ0.001). Patients who received implants because of ventricular tachycardia without hemodynamic compromise had a significantly lower incidence of ventricular fibrillation/flutter (log rankϭ0.01). History of cardiac arrest or ventricular tachycardia with hemodynamic compromise, younger age, and left ventricular involvement were independent predictors of ventricular fibrillation/flutter.
Conclusions-In
A device-based algorithm that alerts patients in case of decreasing intrathoracic impedance facilitates the detection of HF deterioration. Future randomized, controlled trials are needed to test whether the tailored use of intrathoracic impedance monitoring can improve the ambulatory management of patients with chronic HF and an implanted device.
AimsThe HomeGuide Registry was a prospective study (NCT01459874), implementing a model for remote monitoring of cardiac implantable electronic devices (CIEDs) in daily clinical practice, to estimate effectiveness in major cardiovascular event detection and management.Methods and resultsThe workflow for remote monitoring [Biotronik Home Monitoring (HM)] was based on primary nursing: each patient was assigned to an expert nurse for management and to a responsible physician for medical decisions. In-person visits were scheduled once a year. Seventy-five Italian sites enrolled 1650 patients [27% pacemakers, 27% single-chamber implantable cardioverter defibrillators (ICDs), 22% dual-chamber ICDs, 24% ICDs with cardiac resynchronization therapy]. Population resembled the expected characteristics of CIED patients. During a 20 ± 13 month follow-up, 2471 independently adjudicated events were collected in 838 patients (51%): 2033 (82%) were detected during HM sessions; 438 (18%) during in-person visits. Sixty were classified as false-positive, with generalized estimating equation-adjusted sensitivity and positive predictive value of 84.3% [confidence interval (CI), 82.5–86.0%] and 97.4% (CI, 96.5–98.2%), respectively. Overall, 95% of asymptomatic and 73% of actionable events were detected during HM sessions. Median reaction time was 3 days [interquartile range (IQR), 1–14 days]. Generalized estimating equation-adjusted incremental utility, calculated according to four properties of major clinical interest, was in favour of the HM sessions: +0.56 (CI, 0.53–0.58%), P < 0.0001. Resource consumption: 3364 HM sessions performed (76% by nurses), median committed monthly manpower of 55.5 (IQR, 22.0–107.0) min × health personnel/100 patients.ConclusionHome Monitoring was highly effective in detecting and managing clinical events in CIED patients in daily practice with remarkably low manpower and resource consumption.
Purpose: Some implantable cardioverter-defibrillators (ICDs) are now able to monitor intrathoracic impedance. The aim of the study was to describe the use of such monitoring in clinical practice and to evaluate the clinical impact of the fluid accumulation alert feature of these ICDs. Methods and Results: Five hundred thirty-two heart failure (HF) patients implanted with these ICDs were followed up for 11 ± 7 months. A clinical event (CE) was deemed to have occurred if it resulted in hospitalization or milder manifestations of HF deterioration. Three hundred sixty-two acute decreases in intrathoracic impedance (Z events) occurred in 230 patients. Of these episodes, 171 (47%) were associated with a CE within 2 weeks of the Z event. In another 71 (20%) Z events, drug therapy was adjusted despite the absence of overt signs of clinical deterioration. The rate of unexplained Z events was 0.25 per patientyear and 25 hospitalizations were not associated with Z events. The audible alert was disabled in a group of 102 patients (OFF group). HF hospitalizations occurred in 29 (7%) patients in the ON group and 20 (20%, P < 0.001) patients in the OFF group. The rate of combined cardiac death and HF hospitalization was lower in patients with Alert ON (log-rank test, P = 0.007).Conclusions: The ICD reliably detected CE and yielded low rates of unexplained and undetected events. The alert capability seemed to reduce the number of HF hospitalizations by allowing timely detection and therapeutic intervention. (PACE 2009; 32:363-370) heart failure, hospitalization, intrathoracic impedance, implantable defibrillator
COVID-19 outbreak had a major impact on the organization of care in Italy, and a survey to evaluate provision of for arrhythmia during COVID-19 outbreak (March-April 2020) was launched. A total of 104 physicians from 84 Italian arrhythmia centres took part in the survey. The vast majority of participating centres (95.2%) reported a significant reduction in the number of elective pacemaker implantations during the outbreak period compared to the corresponding two months of year 2019 (50.0% of centres reported a reduction of > 50%). Similarly, 92.9% of participating centres reported a significant reduction in the number of implantable cardioverter-defibrillator (ICD) implantations for primary prevention, and 72.6% a significant reduction of ICD implantations for secondary prevention (> 50% in 65.5 and 44.0% of the centres, respectively). The majority of participating centres (77.4%) reported a significant reduction in the number of elective ablations (> 50% in 65.5% of the centres). Also the interventional procedures performed in an emergency setting, as well as acute management of atrial fibrillation had a marked reduction, thus leading to the conclusion that the impact of COVID-19 was disrupting the entire organization of health care, with a massive impact on the activities and procedures related to arrhythmia management in Italy.
HM implemented in the HomeGuide workflow model required <1 hour/month every 100 patients to detect the majority of actionable events with limited administrative workload.
Decreased intrathoracic impedance, low patient activity and low HRV were all independently associated with increased risk for HF hospitalization in HF patients treated with resynchronization therapy. Device-derived diagnostic data may provide valuable and reliable indices for the prognostic stratification of HF patients.
Background: This survey aimed to describe the organizational workflow of cardiac implantable electronic devices (CIEDs) remote monitoring (RM) service in ordinary practice.Methods: A questionnaire was designed for our purpose and completed by 49 sites participating to the Italian Home Monitoring Expert Alliance.Results: A dedicated organizational model for RM was set up for 86% of centers. The median RM team consisted of 2 (Interquartile range [IQR]: 1-3) physicians and 1 (IQR: 0-2) nurse. RM service was available in working hours and the median percentage of patients included was 100% (IQR: 10%-100%) for implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy (CRT) recipients and 5% (IQR:0%-30%) for pacemakers. In-office follow-up was performed every 12 and 6 months for pacemaker and ICD/CRT recipients, respectively. More than 90% of sites used to activate all technical alerts, with a prompt reaction in case of an outof-range parameter. The threshold for atrial fibrillation (AF) daily burden notification in most cases ranged from 2.4 to 7.2 hours. All ventricular arrhythmias alerts were usually switched on: an inappropriate therapy or more than one appropriate episode triggered an urgent in-hospital visit. Concerning heart failure, low CRT percentage pacing alert was always used, while the other available notifications were less frequently switched on.Conclusions: This survey showed that RM service was usually set up with a primary nursing model including on average two responsible physicians and one nurse and mainly offered to ICD/CRT patients. Technical, AF and ventricular arrhythmia alerts triggered prompt reactions, while heart failure related indexes were generally less applied.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.