In CaO-AI 203-and CaF2-CaO-AI,03-slags the soluted water vapour was quantitatively determined with Fourier-Transform-Infrared-(FT-IR-)spectroscopy. The slags were equilibrated at 1500 and 1600°C with definite H 20-and H 20/HF-partial pressures, respectively. The liquid slags were quenched in liquid 0 20. They solidified glassily. Water vapour exists in the slags soluted as OH--ion. For all slags investigated a linear dependence of the integral extinction upon the square root of the H 20-partial pressure, respectively upon HF-partial pressure, was determined. The values of the integral extinction (CaF 2-CaO-AI203-slags) are calibrated by a H 20-doping-technique. The solution enthalpy of H 20 in CaO-AI 203-slags was estimated: endothermal reactions. Interpretation of the vibrational range yielded in a mainly tetrahedral coordination of A13+ with 0 2-and F--ions in the glassy state. By heating the glassily solidified CaO-AI 203-slags were transformed into their crystalline products: shifting of IR-peaks. The CaO-AI 203-and CaF.-CaO-slags were compared with a CaO-Si0 2-AI203-slag.The FT-IR-method is quick. The water content can be estimated with an uncertainty of less than ± 5% and is, therefore, suitable for process control of metallurgical procedures. Wasserdampfloslichkeit in geschmolzenen ESU-Schlacken der SystemeCaO-AI.0 3 und CaF.-CaO-AI.0 3 unter Anwendung der Fourier-Transform-Infrarot-Spektroskopie. In CaD-AI 203-und CaF 2-CaO-AI203-Schlacken wurde geloster Wasserdampf mit der Fourier-Transform-Infrarot-(FT-IR-)Spektroskopie quantitativ bestimmt. Die Schlacken wurden bei 1500 und 1600°C mit definierten H 20-bzw. H 20/HF-PartialdrOcken ins Gleichgewicht gesetzt. Die f10ssigen Schlacken wurden in schwerem Wasser abgeschreckt. Sie erstarrten glasig. Der Wasserdampf lost sich in den Schlacken als OH--Ion auf. FOr aile untersuchten Schlacken wurde lineare Abhanqiqkeit zwischen integraler Extinktion und der Quadratwurzel des H 20-Partialdruckes bzw. HF-Partialdruckes bestimmt. Die integrale Extinktion (CaF 2-CaO-AI203-Schlacken) wurde durch eine H,o-Dotierungstechnik geeicht. Die Losunqsenthalple des Wassers in CaO-AI 203-Schlacken wurde bestimmt: endotherme Reaktionen. Die Auswertung des Schwingungsbereiches der Schlackenkomponenten ergab, daB AI'+ bevorzugt mit 0 2-bzw. F--Ionen tetraedrisch koordiniert ist. Umkristallisation der glasig erstarrten CaO-AI 203-Schlacken wurde durch Tempern erreicht: Verschiebung von IR-Peaks. Die CaO-AI,03-und CaF 2-CaO-AI203-Schlacken wurden mit einer CaO-Si0 2-AI203-Schlacke verglichen. Die FT-IR-Methode ist schnell. Der Wassergehalt kann mit einem Fehler unter ± 5 % bestimmt werden. Sie ist deshalb zur ProzeBkontrolle bei metallurgischen Ablauten geeignet.
Water vapour is soluted in liquid CaO-AI,03-slags as Ol-t-ion. To determine the diffusion coefficient O(OH-) a capillary technique is used. Roughly 5 cm long platinum capillaries filled with liquid slag are equilibrated at 1500 and 1600 "C and P(H,O) = 0.2 bar different times and then are quenched in liquid D,O. By dividing these capillaries into roughly 3 mm long segments enough sample substance is won to obtain FT-IR spectra of the OH-band. From measurement of the integral extinction of the OH-band and Ol-r-concentration profile through the capillary is obtained. FT-IR-spectroscopy is very suitable for this capillary technique because it needs only very little sample substance. Diffusion des Hydroxid-Ions in f1iissigen CaO-AI203-Schlacken unter Anwendung der Fourier-Transform-Infrarot-Spektroskopie. Wasserdampf lost sich in tlussiqen CaO-AI,03-Schlacken als OH--Ion. Zur Bestimmung des Diffusionskoeffizienten O(OW) wird eine Kapillartechnik benutzt. Eine mit flussiqer Schlacke gefullte, rd. 5 cm lange Platinkapillare wird bei 1500 und 1600 "C und P(H20) = 0,2 bar verschiedene Zeiten mit Wasserdampf ins Gleichgewicht gesetzt und danach in tlusslqern D 20 abgeschreckt. Durch Zerlegung dieser Kapillaren in rd. 3 mm lange Segmente wird genug Probensubstanz zur Aufnahme von FT-IR-Spektren
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.