PurposeDosimetric accuracy is critical when switching a patient treated with stereotactic body radiation therapy (SBRT) or stereotactic fractionated radiotherapy (SRT) among beam‐matched linacs. In this study, the dose delivery accuracy of volumetric modulated arc therapy (VMAT) plans for SBRT/SRT patients were evaluated on three beam‐matched linacs.MethodBeam data measurements such as percentage depth dose (PDD 10), beam profiles, output factors, and multi‐leaf collimator (MLC) leaf transmission factor for 6 MV photon beam were performed on three beam‐matched linacs. The Edge™ diode detector was used for measurements of beams of field size less than 5 × 5 cm2. Ten lung and 15 brain plans were generated using VMAT with the same beam model. Modulation complexity score of the VMAT plan (MCSv) was used as a plan complexity indicator. Doses were measured using ArcCHECK™ and GafChromic™ EBT3 films. The measurements were compared with calculated doses through absolute dose gamma comparison using 3%/2 mm and 2%/2 mm criteria. Correlation between difference in passing rates among beam‐matched linacs and MCSv was evaluated using the Pearson coefficient. Point doses were measured with the A1SL micro ion chamber.ResultsDifference in beam outputs, beam profiles, and MLC leaf transmission factors of beam‐matched linacs were all within ±1%, except the difference in output factor for 1 × 1 cm2 field between linac 1 and 3 (1.3%). For all 25 cases, passing rates of measured doses on three linacs were all higher than 90% when using 2%/2 mm gamma criteria. The average difference in point dose measurements among three beam‐matched linacs was 0.1 ± 0.2% (P > 0.05, one‐way ANOVA).ConclusionMinimal differences in beam parameters, point doses, and passing rates among three linacs proved the viability of swapping SBRT/SRT using VMAT among beam‐matched linacs. The effect of plan complexity on passing rate difference among beam‐matched linacs is not statistically significant.
We have investigated the influence of electron irradiation on tin whisker growth. Sputtered tin samples exposed to electron beam of 6 MeV energy exhibited fast whisker growth, while control samples did not grow any whiskers. The statistics of e-beam induced whiskers was found to follow the log-normal distribution. The observed accelerated whisker growth is attributed to electrostatic effects due to charges trapped in an insulating substrate. These results offer promise for establishing whisker-related accelerated life testing protocols.
A systematic approach of combining LDR prostate brachytherapy with hyperthermia is described, and its ability to provide sufficient and uniform temperature distributions in realistic patient-specific implants evaluated. A combination of TB and HT-only seeds may be used to produce a uniform temperature distribution in a defined target. Various modeled changes to their design, such as optimization of their Curie temperature, improve their ability to overcome the thermal effects of blood perfusion. The enhanced ISA of the TB and HT-only seeds must be taken into account for dose calculations, but is manageable.
We have investigated the impact of strong (∼10 4 V/cm) electric fields on the development of Zn whiskers. The original samples, with considerable whisker infestation were cut from Zn-coated steel floors and then exposed to electric fields stresses for 10-20 hours at room temperature. We used various electric field sources, from charges accumulated in samples irradiated by: (1) the electron beam of a scanning electron microscope (SEM), (2) the electron beam of a medical linear accelerator, and (3) the ion beam of a linear accelerator; we also used (4) the electric field produced by a Van der Graaf generator. In all cases, the exposed samples exhibited a considerable (tens of percent) increase in whiskers concentration compared to the control sample. The acceleration factor defined as the ratio of the measured whisker growth rate over that in zero field, was estimated to approach several hundred. The statistics of lengths of e-beam induced whiskers was found to follow the log-normal distribution known previously for metal whiskers. The observed accelerated whisker growth is attributed to electrostatic effects. These results offer promise for establishing whisker-related accelerated life testing protocols. C 2016 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license
Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulating thermal properties. Methods:The new seed's geometry is based on the standard BEST Model 2301 125 I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni-Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50• C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni-Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni-Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and CT images, and a preliminary experiment demonstrates thermal self-regulation and adequate heating of a tissue-mimicking phantom by seed prototypes. The effect of self-shielding of the seed against the external magnetic field is small, and only minor thermal stress is induced in heating of the seeds from room temperature to well above the seed operating temperature. With proper selection of magnetic field parameters, the thermal dose distribution of an arrangement of TB and hyperthermia-only seeds may be made to match with its radiation dose distribution. Conclusions:The presented analyses address several practical considerations for manufacturing of the proposed TB seeds and identify critical issues for the prototype implementation. The authors' preliminary experiments demonstrate close agreement with the modeling results, confirming the feasibility of combining sources of heat and radiation into a single thermobrachytherapy seed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.