The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer
Articles you may be interested inCustom single-photon avalanche diode with integrated front-end for parallel photon timing applications Rev. Sci. Instrum. 83, 033104 (2012); 10.1063/1.3692737Actively quenched singlephoton avalanche diode for high repetition rate timegated photon counting Rev. Sci. Instrum. 67, 55 (1996); 10.1063/1.1146551Photoluminescence lifetime microscope spectrometer based on timecorrelated singlephoton counting with an avalanche diode detector Rev.Performance comparison of a singlephoton avalanche diode with a microchannelplate photomultiplier in time correlated singlephoton counting Rev. Sci. Instrum.Single photon avalanche diodes (SP ADs) are avalanche photodiodes specifically designed for reverse bias operation above the breakdown voltage and used for detecting single optical photons. A new silicon epitaxial device structure was designed to give improved timing performance with respect to previous SP ADs. Extensive tests were carried out in order to establish the timing resolution of the device in time correlated photon counting (TCPC). The timing resolution of the SPAD in terms of its full-width at half-maximum (FWHM) contribution to the overall instrumental response width is 20 ps with the detector cooled to -65 ·C, and 28 ps at room temperature. This is the highest resolution so far reported for solid-state single-photon detectors. In vacuum tubes, comparable results are obtained only with special microchannel-plate photomultipliers (MCP-PMT). Results from time-resolved photoluminescence measurements in Ga.t\.s demonstrate the power of the TCPC technique when used with the new SPAD detector. With the excellent timing resolution of the SPAD and the well-known advantages ofTCPC systems (high sensitivity, linearity, etc. ), various applications are foreseen in areas so far dominated by streak cameras.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.