BackgroundUnder the ‘Choosing Wisely’ (CW) framework, professional organisations internationally have advocated limiting imaging for asymptomatic patients following curative cancer therapy, based on limited value and high cost. F18-fluorodeoxyglucose (FDG) positron emission tomography-CT (PET/CT) was widely adopted locally for surveillance lymphoma imaging after 2004.ObjectivesPrior to ratification of a local CW recommendation to limit surveillance imaging in lymphoma, we aimed to assess: (A) performance characteristics of surveillance FDG-PET/CT; (B) rates, clinical consequences and costs of false positives (FP); and (C) patients and professionals’ attitudes towards overuse.MethodsMixed methods (quantitative and qualitative) study. We analysed surveillance FDG-PET/CT results of two patient cohorts (n1=215 Hodgkin lymphoma and non-Hodgkin lymphoma; n2=203 Hodgkin lymphoma only). FPs were defined by negative biopsy or clinical follow-up. We held focus group discussions and in-depth interviews eliciting attitudes of 26 patients and 11 clinicians, respectively.ResultsFPs were observed in 25.1% (95% CI 20.5 to 30.5) per scan—cohort 1, and 41.7% (95% CI 37.9 to 45.6) per patient—cohort 2, engendering frequent additional testing. Specific characteristics and location of findings altered the FP rate. The estimated cost per relapse detected was $50 000 (cohort 2). Patients sought reassurance via surveillance imaging, which they considered highly accurate, yet stressful. Aware of radiation risks, they were largely unconcerned about consequences of FPs. Confidence in the treating physicians was an important factor in patients’ acceptance of forgoing imaging. Clinicians, frequently under patient pressure to order imaging, generally believed that it did not affect prognosis (with important exceptions), welcomed professional guidelines, but rejected regulatory restrictions on its use.ConclusionAcceptance of CW recommendations to limit overuse may be enhanced by quantitative data on consequences and costs of surveillance imaging, supplemented by qualitative data on patient and physician attitudes.
using the fixed effects (Z = 1.39; p = 0.16) models. Comparing Bishop score and cervical length, it can be seen that those data coming from Bishop score were highly favourable. However, when tested for significance at 0.05 level, it yielded a value of 1.39. This is lower than the z-value of 1.96 at 0.05 level.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.