The feasibility of measuring caffeine clearance from saliva (SCl) was assessed in ambulatory patients with liver disease and in a control group, and the results were compared with quantitative liver function tests. For this purpose, the subjects were given 280 mg caffeine p.o. in decaffeinated coffee powder between noon and 4 p.m., and caffeine concentrations were measured in saliva (using an enzyme immunoassay) before bedtime and upon arising. In the cirrhotics (n = 29), SCl was 0.58 +/- S.D. 0.45 ml per min X kg, thus being reduced to approximately one-third of drug-free, nonsmoking controls (1.53 +/- 0.46, n = 18); although patients with noncirrhotic liver disease showed intermediate values (0.95 +/- 0.47), their reduction in SCl was significant (p less than 0.001). SCl was correlated with indocyanine green fractional clearance, galactose elimination capacity and aminopyrine breath test; however, the closest relationship (Rs = 0.80) was observed with the aminopyrine breath test. It is suggested that the measurement of SCl represents a noninvasive and innocuous procedure for quantifying hepatic microsomal function, and is suitable for routine use. Since a.m. saliva concentrations of caffeine are highly correlated (Rs = -0.94) with SCl, further simplification of the test to a single-point measurement appears possible.
The topical application of triclosan as an antistaphylogenic antiseptic has proven beneficial in atopic dermatitis. Especially in lipophilic carriers, triclosan is applied in a concentration range between 1 and 5%, usually 2%. However, as a phenol, triclosan is not undisputed and may result in local exacerbation of the disease by eliciting irritative secondary reactions, especially in high concentrations. Chlorhexidine is also an antiseptic which is very effective against Staphylococciand nearly equivalent to triclosan with respect to its antistaphylogenic efficacy. In light of this, the combination of the two active substances in very low concentrations offers a possible option of using the additive effects of the two substances to minimize the risk of side effects. In a uniform W/O emulsion carrier alternatively containing 0.3% triclosan combined with 0.34% chlorhexidine dihydrochloride or 2.0% triclosan, the antibacterial efficacy against Gram-positive skin bacteria could be proven in a preclinical comparison with a reference preparation containing fusidic acid. Subsequently, the pathogen-reducing effect was examined in a clinical study of the influence on clinical severity in patients with atopic dermatitis. Both investigation methods showed that the two test preparations were slightly inferior to the reference preparation, but result in the same degree of pathogen reduction and improvement in the severity of existing atopic dermatitis in direct comparison. The overall results support the conclusion that a combination of triclosan and chlorhexidine in low concentrations as well as the existing antiseptic standard of a 2% triclosan preparation are suitable for pathogen reduction and thus for improving atopic dermatitis.
Clotrimazole was superior to nystatin with respect to reduction in symptom score and GA. Microbiological cure rate was 100% for both agents. Both treatments were safe and well-tolerated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.