Aims. The Spectrometer Telescope for Imaging X-rays (STIX) on Solar Orbiter is a hard X-ray imaging spectrometer, which covers the energy range from 4 to 150 keV. STIX observes hard X-ray bremsstrahlung emissions from solar flares and therefore provides diagnostics of the hottest (⪆10 MK) flare plasma while quantifying the location, spectrum, and energy content of flare-accelerated nonthermal electrons. Methods. To accomplish this, STIX applies an indirect bigrid Fourier imaging technique using a set of tungsten grids (at pitches from 0.038 to 1 mm) in front of 32 coarsely pixelated CdTe detectors to provide information on angular scales from 7 to 180 arcsec with 1 keV energy resolution (at 6 keV). The imaging concept of STIX has intrinsically low telemetry and it is therefore well-suited to the limited resources available to the Solar Orbiter payload. To further reduce the downlinked data volume, STIX data are binned on board into 32 selectable energy bins and dynamically-adjusted time bins with a typical duration of 1 s during flares. Results. Through hard X-ray diagnostics, STIX provides critical information for understanding the acceleration of electrons at the Sun and their transport into interplanetary space and for determining the magnetic connection of Solar Orbiter back to the Sun. In this way, STIX serves to link Solar Orbiter’s remote and in-situ measurements.
The Spectrometer/Telescope for Imaging X-rays (STIX) is a remote sensing instrument on-board the ESA Solar Orbiter spacecraft. STIX is designated to the study of energetic phenomena in solar flares. A Fourier-imaging technique using tungsten grid collimators in front of CdTe pixel detectors is employed, covering the 4 to 150 keV energy range with a full-width-half maximum resolution around 1 keV at low energies.Acrorad CdTe detectors of 1 mm thickness with a planar aluminum Schottky contact are used as basis for a subsequent patterning process into eight large pixels, four small pixels, and a guard ring. The patterning is done by means of microfabrication technologies. The area of the patterned sensor is 10×10 mm 2 .Test equipment has been developed for selecting the detectors with best performance prior to integration with the read-out system, and for qualification purposes. The set-up allows pixel-based dark current measurements at low temperatures. Pixel dark currents below 60 pA are needed to avoid excess noise in the read-out ASIC. The best pixels show dark currents below 10 pA at 300 V bias and −20°C. Spectroscopic measurements with 133 Ba sources confirm the good performance.This paper briefly explains the mission context of the CdTe detectors and then gives details of the production and testing procedures. Typical results are shown, with emphasis on performance degradation studies from displacement damage by proton irradiation. This is expected to be the dominant degradation mechanism for this application.
Caliste-SO is a hybrid detector integrating in a volume of 12 × 14 × 18 mm 3 a 1 mm-thick CdTe pixel detector, a frontend IDeF-X HD ASIC and passive parts to perform high resolution spectroscopy in the 4-200 keV energy range with high count rate capability (10 4 -10 5 photons/s/cm2). The detector hybridization concept was designed by CEA and 3D-Plus to realize CdTe cameras for space astronomy missions with various pixel patterns. For the STIX instrument onboard the Solar Orbiter mission, the imaging system is made by 32 collimators that sample the visibilities of the spatial Fourier transform and doesn't require fine pitch pixels. The Al-Schottky CdTe detectors produced by Acrorad are then patterned and tested by the Paul Scherrer Institute to produce 12 pixels surrounded by a guard ring within 1 cm 2 . Electrical and spectroscopic performance tests of the Caliste-SO samples are performed in France at key manufacturing steps, before sending the samples to the principal investigator to mount them in the Detector Electronics Module of STIX in front of each collimator. Four samples were produced in 2013 to be part of the STIX engineering model. Best pixels show an energy resolution of 0.7 keV FWHM at 6 keV (1 keV resolution requirement for STIX) and a low-level detection threshold below 3 keV (4 keV requirement for STIX). The paper describes the design and the production of Caliste-SO and focuses on main performance tests performed so far to characterize the spectrometer unit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.