Experimental results are given in Tables S1 and S2. This information is available free of charge via the Internet at http://pubs.acs.org/.International audienceHydrofluoroalkenes, like hexafluoropropylene, can be considered as new working fluids for refrigeration systems and consequently volumetric and critical property data are required. In this study, a vibrating tube densitometer technique was used to determine densities at nine different temperatures between (263 and 358) K, and pressures between (0.04 and 15) MPa. The experimental uncertainties are (0.0003 and (0.0006 MPa for pressure, ( 0.02 K for temperature, ( 0.5% (relative) for vapor densities, and (0.05% for liquid densities. A different equipment based on static method is used for the determination of pure component vapor pressures for temperatures between (231 and 359) K. The experimental uncertainties are (0.0005 MPa for pressure and(0.02 K for the temperature. Critical properties have been determined by direct measurement and also from utilization of experimental densities considering the asymptotic scaling law behavior. The Patel Teja and crossover Patel Teja equations of state are used to correlate the data
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.