We performed a prospective random study to assess possible thyroid stunning by a 185-MBq iodine-131 dose used to diagnose thyroid remnants. Patients with differentiated thyroid carcinoma were included after total or near-total thyroidectomy. They were randomly assigned to two groups. In group 0 (G0, 32 patients), iodine-123 administration only was used to diagnose thyroid remnants and/or metastasis, so that no thyroid stunning by 131I would occur. In group 1 (G1, 19 patients), diagnostic imaging was performed with 123I and 185 MBq 131I. 123I imaging was less sensitive than 131I imaging in identifying thyroid remnants in both groups (94%). Thyroid uptake of 123I was measured in both groups (at 2 h) and was not significantly different between the groups. Patients with thyroid remnants who remained in the study (28/32 in G0, 17/19 in G1) were treated with 370 MBq 131I, 5 weeks after treatment (mean time, range 12-84 days). In 12/17 G1 patients thyroid uptake measurement was repeated immediately before treatment. Uptake was equal to 1.97% +/- 0.71% and significantly lower (P < 0.05) than the previous measurement (3.76% +/- 1.50%). Patients were imaged 7 days after administration of the therapeutic dose and the images were compared with the diagnostic images. In 28/28 G0 patients thyroid remnants were unchanged and clearly seen. In 5/17 G1 patients, however the remnants were hardly identified, although they had been clearly seen at the time of diagnosis. We conclude the following: (1) a diagnostic dose of 185 MBq 131I decreases thyroid uptake for several weeks after administration and can impair immediate subsequent 131I therapy; (2) 123I is slightly less sensitive than 131I in identifying thyroid remnants; and (3) the need to scan for thyroid remnants remains to be confirmed, since only 2/51 patients enrolled in this study were not treated with 131I.
FDG-PET/CT seems to be an interesting tool for the early evaluation of response to sunitinib in metastatic RCC. Larger studies are needed to confirm these preliminary results and establish a prognostic value for PET/CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.