PurposeTo assess the setup errors in radiation therapy for thoracic tumors patients of different somatotypes, and to seek an individualized mathematical basis for defining the planning target volume (PTV).MethodsSixty patients with thoracic tumors were divided into four somatotypes according to their body mass index (BMI), and their body positions were setup by two groups of technicians independently. CT simulations were performed and the reconstructed radiography was digitally generated as reference images for location verification and error measurement. By setting positioning error ranges, the within‐range positioning correction rate was compared among groups.ResultsPosition setups for patients in the emaciated group, moderate group, and overweight group were relatively stable (with minor setup error differences between the two groups of technicians). In emaciated group, moderate group, overweight group, and obese group, setup errors in the right–left direction (R‐L) were 2.2 ± 1.3 mm, 2.2 ± 1.6 mm, 3.9 ± 3.1 mm, and 8.8 ± 3.5 mm, respectively; whereas the setup errors in the four groups in the superior–inferior(S‐I) direction were 2.4 ± 1.8 mm, 2.1 ± 1.9 mm, 3.2 ± 2.6 mm, and 5.4 ± 3.5 mm, and in the anterior–posterior (A‐P) direction were 2.2 ± 1.7 mm, 1.9 ± 1.9 mm, 3.2 ± 2.9 mm, and 6.2 ± 4.2 mm, respectively. Moreover, in the moderate group, the positioning correction rate in the three directions (R‐L, S‐I, and A‐P) was 20%, 9%, 8% within the error range of 5–10 mm, and 3%, 0%, 1% with a more than 10 mm error range. However, in overweight group and obese group, the positioning correction rate in these three directions (also with a more than 10 mm error range) was 23%, 27%, 19% and 21%, 16%, 23%, respectively.ConclusionsIn radiation therapy for patients with thoracic tumors, the definition of PTV should be individualized. Meanwhile, with the increase in BMI, positioning correction rate has a tendency to rise too.
Background: Lung cancer is a leading cause of morbidity and mortality worldwide. Radiotherapy for lung cancer is beneficial in both the radical and palliative settings, and technologic advances in recent years now afford an opportunity for this treatment to be more targeted than ever before. Although the delivery of more accurate forms of radiotherapy has minimized the risks of side-effects, how to utilize this treatment to optimize outcomes remains questionable. This study aimed to evaluate the accuracy of cone beam computed tomography (CBCT) image registration used in image-guided radiotherapy, providing reasonable guidance for clinic application of CBCT in lung cancer. Methods: A total of 53 patients with lung carcinoma including 34 central and 19 peripheral lesions were collected in this study. Varian-IX linear accelerator on-board imaging (OBI) system was used to acquire CBCT scans in threedimensional (3D) conformal radiotherapy before delivery. Different regions (whole lung/target/vertebrae/ipsilateral structure) were manually registered, and the position deviation and the registration time were analyzed. Results: It was suggested that 34 cases belonged to central type and 19 cases belonged to peripheral type. The volume of left lung and right lung was 1242.98 ± 452.46 cc, 1689.69 ± 574.31 cc, respectively. Tumor size was 6.65 ± 3.87 cm in diameter, and 129.67 ± 136.48 cc in volume. The percentage of left lung and right lung was 6.17 ± 1.24%, 4.74 ± 0.38%, respectively. The position deviation value and absolute value of image registration methods of X, Y and Z axis were not significant (P > 0.05). However, registration time (s) between whole lung registration group, tumor registration group, vertebral body registration group, affected lung registration group, and artificial registration group, was 3.651 ± 0.867 s, 1.144 ± 0.129 s, 1.226 ± 0.126 s, 2.081 ± 0.427 s, 179.491 ± 71.975 s, respectively. The differences were significant (P < 0.05). The registration differences between small tumor group and large tumor group were not statistically significant (P > 0.05). Conclusion: The automatic image matching of OBI is accuracy and high reliability in recognition of offset error. Registering body or ipsilateral structure is recommended to be used in CBCT for lung cancer.
Esophageal squamous cell carcinoma (ESCC) is a leading cause of cancer-related deaths worldwide. And radical synchronized chemoradiotherapy has become an important treatment measures for this disease. It is necessary to define the therapeutic target zone based on computer tomography(CT)-images for precise radiotherapy. Therefore, we retrospectively analyzed the regularity of lymph node metastasis in lower cervical section of thoracic esophageal cancer based on CT-images and discussed the range of radiotherapy in supraclavicular zone. The lower cervical lymphatic drainage area was divided into cervical tracheoesophageal groove (CTG), medial supraclavicular zone (MSC zone) and lateral supraclavicular zone (LSC zone) based on CT-images. We found that the rate of lymph node metastasis to medial CTG and MSC zone was relatively high. And rate of lymph node metastasis to the above two zones from middle thoracic section was on an increasing trend with the progress of T stage. Patients at stage T3 and T4 with lymph node metastasis in tracheoesophageal groove in middle thoracic section showed a higher rate of lymph node metastasis in MSC zone. These results demonstrated that the CTG and MSC zone should be clinically included in the supraclavicular target zone for radical radiotherapy, and the T-stage and tumor location should be considered simultaneously.
Concurrent chemoradiotherapy is one of the main treatments for rectal cancer. Bone marrow suppression is one of the critical factors that affect the progress of radiotherapy. We aimed to explore the association of incidence of acute bone marrow suppression with dose-volume parameters of pelvic bone marrow among rectal cancer patients with concurrent chemoradiotherapy. We retrospectively analyzed 50 rectal cancer patients for multivariate logistic regression analyses. Three subdomains of pelvic bone marrow (PBM), bilateral ilium (IBM), lower pelvis (LPBM), and lumbosacral spine (LSBM) were assigned. The radiation dose-volume parameters from the three subdomains and the whole pelvis were evaluated. Compared to Grade 0-1 leukopenia patients, ≥Grade 2 leukopenia patients exhibited significantly higher levels of IBM V20, V25, V35, mean dose (Dmean), LPBM V20, V25, V30, LSBM V15, PBM V15, V20, and PTV. The PBM V20 of ≥Grade 2 neutropenia patients was significantly higher than that of Grade 0-1 neutropenia patients. Multivariate analysis have demonstrated that IBM V20 and LSBM V15 were the independent factors affecting ≥ Grade 2 leukopenia. There is a correlation between low dose-volume parameters with acute bone marrow suppression. IBM V20, LSBM V15 and PBM V20 can be employed as the predictors of acute bone marrow suppression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.