Abstract. A data set containing more than 6 years (February 2009 to present) of radiance spectra for carbon dioxide (CO 2 ) and methane (CH 4 ) observations has been acquired by the Greenhouse gases Observing SATellite (GOSAT, available at http://data.gosat.nies.go.jp/ GosatUserInterfaceGateway/guig/GuigPage/open.do), nicknamed "Ibuki", Thermal And Near infrared Sensor for carbon Observation Fourier Transform Spectrometer (TANSO-FTS). This paper provides updates on the performance of the satellite and TANSO-FTS sensor and describes important changes to the data product, which has recently been made available to users. With these changes the typical accuracy of retrieved column-averaged dry air mole fractions of CO 2 and CH 4 (X CO 2 and X CH 4 , respectively) are 2 ppm or 0.5 % and 13 ppb or 0.7 %, respectively. Three major anomalies of the satellite system affecting TANSO-FTS are reported: a failure of one of the two solar paddles in May 2014, a switch to the secondary pointing system in January 2015, and most recently a cryocooler shutdown and restart in August 2015. The Level 1A (L1A) (raw interferogram) and the Level 1B (L1B) (radiance spectra) of version V201 described here have longterm uniform quality and provide consistent retrieval accuracy even after the satellite system anomalies. In addition, we discuss the unique observation abilities of GOSAT made possible by an agile pointing mechanism, which allows for optimization of global sampling patterns.
This work describes the radiometric calibration of the short-wave infrared (SWIR) bands of two instruments aboard the Greenhouse gases Observing SATellite (GOSAT), the Thermal And Near infrared Sensor for carbon Observations Fourier Transform Spectrometer (TANSO-FTS) and the Cloud and Aerosol Imager (TANSO-CAI). Four vicarious calibration campaigns (VCCs) have been performed annually since June 2009 at Railroad Valley, NV, USA, to estimate changes in the radiometric response of both sensors. While the 2009 campaign (VCC 2009 ) indicated significant initial degradation in the sensors compared to the prelaunch values, the results presented here show that the stability of the sensors has improved with time. The largest changes were seen in the 0.76 μm oxygen A-band for TANSO-FTS and in the 0.380 and 0.674 μm bands for TANSO-CAI. This paper describes techniques used to optimize the vicarious calibration of the GOSAT SWIR sensors. We discuss error reductions, relative to previous work, achieved by using higher quality and more comprehensive in situ measurements and proper selection of reference remote sensing Manuscript products from the Moderate Resolution Imaging Spectroradiometer used in radiative transfer calculations to model top-of-theatmosphere radiances. In addition, we present new estimates of TANSO-FTS radiometric degradation factors derived by combining the new vicarious calibration results with the time-dependent model provided by Yoshida et al. (2012), which is based on analysis of on-board solar diffuser data. We conclude that this combined model provides a robust correction for TANSO-FTS Level 1B spectra. A detailed error budget for TANSO-FTS vicarious calibration is also provided. Index Terms-Carbon dioxide (CO 2 ), Greenhouse gases Observing SATellite (GOSAT), short-wave infrared (SWIR), Thermal And Near infrared Sensor for carbon Observations (TANSO), vicarious calibration.
Abstract. The Thermal And Near infrared Sensor for carbon Observation Fourier-Transform Spectrometer (TANSO-FTS) onboard the Greenhouse gases Observing SATellite (GOSAT) (nicknamed "Ibuki") has been providing global space-borne observations of carbon dioxide (CO 2 ) and methane (CH 4 ) since 2009. In this paper, we first describe the version V150.151 operational Level 1 algorithms that produce radiance spectra from the acquired interferograms. Second, we will describe the on-orbit characteristics and calibration of TANSO-FTS. Overall function and performance such as signal to noise ratio and spectral resolution are within design objectives. Correction methods of small onorbit degradations and anomalies, which have been found since launch, are described. Lastly, calibration of TANSO Cloud and Aerosol Imager (TANSO-CAI) are summarized.
Abstract. The Japanese Greenhouse gases Observing SATellite-2 (GOSAT-2), in orbit since 29 October 2018, follows up the GOSAT mission, itself in orbit since 23 January 2009. GOSAT-2 monitors carbon dioxide and methane in order to increase our understanding of the global carbon cycle. It simultaneously measures carbon monoxide emitted from fossil fuel combustion and biomass burning and permits identification of the amount of combustion-related carbon. To do this, the satellite utilizes the Thermal and Near Infrared Sensor for Carbon Observation Fourier-Transform Spectrometer-2 (TANSO-FTS-2). This spectrometer detects gas absorption spectra of solar radiation reflected from the Earth's surface in the shortwave-infrared (SWIR) region as well as the emitted thermal infrared radiation (TIR) from the ground and the atmosphere. TANSO-FTS-2 can measure the oxygen A band (0.76 µm), weak and strong CO2 bands (1.6 and 2.0 µm), weak and strong CH4 bands (1.6 and 2.3 µm), a weak CO band (2.3 µm), a mid-wave TIR band (5.5–8.4 µm), and a long-wave TIR band (8.4–14.3 µm) with 0.2 cm−1 spectral sampling intervals. TANSO-FTS-2 is equipped with a solar diffuser target, a monochromatic light source, and a blackbody for spectral radiance calibration. These calibration sources permit characterization of time-dependent instrument changes in orbit. The onboard-recalibrated instrumental parameters are considered in operational level-1 processing and released as TANSO-FTS-2 level-1 version 102102 products, which were officially released on 25 May 2020. This paper provides an overview of the TANSO-FTS-2 instrument, the level-1 processing, and the first-year in-orbit performance. To validate the spectral radiance calibration during the first year of operation, the spectral radiance of the version 102102 product is compared at temporally coincident and spatially collocated points from February 2019 to March 2020 with TANSO-FTS on GOSAT for SWIR and with AIRS on Aqua and IASI on METOP-B for TIR. The spectral radiances measured by TANSO-FTS and TANSO-FTS-2 agree within 2 % of the averaged bias and 0.5 % standard deviation for SWIR bands. The agreement of brightness temperature between TANSO-FTS-2 and AIRS–IASI is better than 1 K in the range from 220 to 320 K. GOSAT-2 not only provides seamless global CO2 and CH4 observation but also observes local emissions and uptake with an additional CO channel, fully customized sampling patterns, higher signal-to-noise ratios, and wider pointing angles than GOSAT.
Vicarious calibration is the determination of an on-orbit sensor’s radiometric response using measurements over test sites such as Railroad Valley (RRV), Nevada. It has the highest accuracy when a remote sensor’s view angle is aligned with that of the surface measurements, namely at a nadir view. For view angles greater than 10, the dominant error is the uncertainty in the off-nadir correction factor. The factor is largest in the back-scatter principal plane and can reach 20%. The Orbiting-Carbon Observatory has access to a number of datasets to determine this deviation. These include measurements from field instruments such as the Portable Apparatus for Rapid Acquisition of Bidirectional Observation of the Land and Atmosphere (PARABOLA), as well as satellite measurements from Multi-angle Imaging SpectroRadiometer (MISR) and MODerate resolution Imaging Spectroradiometer (MODIS). The correction factor derived from PARABOLA is consistent in time and space to within 2% for view angles as large as 30. Field spectrometer data show that the correction term is spectrally invariant. For this reason, a time-invariant model of RRV surface reflectance, along with empirically derived coefficients, is sufficient to use in the calibration of off-nadir sensors, provided there has been no recent rainfall. With this off-nadir correction, calibrations can be expected to have uncertainties within 5%.
Emissions of atmospheric methane (CH4), which greatly contributes to radiative forcing, have larger uncertainties than those for carbon dioxide (CO2). The Thermal And Near-infrared Sensor for carbon Observation Fourier-Transform Spectrometer (TANSO-FTS) onboard the Greenhouse gases Observing SATellite (GOSAT) launched in 2009 has demonstrated global grid observations of the total column density of CO2 and CH4 from space, and thus reduced uncertainty in the global flux estimation. In this paper, we present a case study on local CH4 emission detection from a single-point source using an available series of GOSAT data. By modifying the grid observation pattern, the pointing mechanism of TANSO-FTS targets a natural gas leak point at Aliso Canyon in Southern California, where the clear-sky frequency is high. To enhance local emission estimates, we retrieved CO2 and CH4 partial column-averaged dry-air mole fractions of the lower troposphere (XCO2 (LT) and XCH4 (LT)) by simultaneous use of both sunlight reflected from Earth’s surface and thermal emissions from the atmosphere. The time-series data of Aliso Canyon showed a large enhancement that decreased with time after its initial blowout, compared with reference point data and filtered with wind direction simulated by the Weather Research and Forecasting (WRF) model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.