Objective. Time-of-flight (TOF) and depth-of-interaction (DOI) are well recognized as important information to improve PET image quality. Since such information types are not correlated, many TOF-DOI detectors have been developed but there are only a few reports of high-resolution detectors (e.g. 1.5 mm resolution) for brain PET systems. Based on the DOI detector, which enables single-ended readout by optically coupling a pair of crystals and having a loop structure, we have developed the crosshair light sharing (CLS) PET detector that optically couples the four-loop structure, consisting of quadrisected crystals comparable in size to a photo-sensor, to four photo-sensors in close proximity arranged in a windmill shape. Even as a high-resolution detector, the CLS PET detector could obtain both TOF and DOI information. The coincidence resolving time (CRT) of the CLS PET detector needs to be further improved, however, for application to the brain PET system. Recently, a fast LGSO crystal was developed which has advantages in detection efficiency and CRT compared to the GFAG crystal. In this work, we developed the CLS PET detector using the fast LGSO crystal for the TOF-DOI brain PET system. Approach. The crystals were each 1.45 × 1.45 × 15 mm3 and all surfaces were chemically etched. The CLS PET detector consisted of a 14 × 14 crystal array optically coupled to an 8 × 8 MPPC array. Main results. The fast LGSO array provided 10.1% energy resolution at 511 keV, 4.7 mm DOI resolution at 662 keV, and 293 ps CRT with the energy window of 440–620 keV. Significance. The developed CLS PET detector has 290% higher coincidence sensitivity, 30% better energy resolution, and 32% better time resolution compared to our previous CLS PET detector.
To improve positron emission tomography (PET) image quality, depth-of-interaction (DOI) information and timeof-flight (TOF) information are key technologies. In this work, we developed the DOI-TOF detector based on our original single-ended readout scheme with the continuous layered gadolinium fine aluminum garnet (GFAG) array. The size of each GFAG crystal is 1.45 × 1.45 × 20 mm 3 . The multipixel photon counter (MPPC) used as a photo sensor has a surface area of 3.0 × 3.0 mm 2 . One pair of crystals coupled with a partial optical window is arranged across two MPPCs. Boundaries without the partial optical window are covered with optical reflectors. Each pair is coupled with paired MPPCs of different patterns. Crystal identification is obtained from paired MPPCs of different patterns and output rates. By limiting the spread of scintillation light, the proposed DOI detector based on the local centroid calculation was expected to improve crystal response, including the edge. For performance comparison, we prepared three discrete layers of the GFAG array with the same total thickness. For the continuous layer, the DOI resolution, the energy resolution and the timing resolution of the pair of detectors are 4.7 mm, 14%, and 402 ps, respectively. Their respective values are 29%, 20%, and 33% better than those with the three discrete layers. Index Terms-Depth of interaction (DOI), detector, positron emission tomography (PET), time of flight (TOF).
Objective. In carbon ion therapy, the visualization of the range of incident particles in a patient body is important for treatment verification. In-beam positron emission tomography (PET) imaging is one of the methods to verify the treatment in ion therapy due to the high quality of PET images. We have shown the feasibility of in-beam PET imaging of radioactive 15O and 11C ion beams for range verification using our OpenPET system. Recently, we developed a whole gamma imager (WGI) that can simultaneously work as PET, single gamma ray and triple gamma ray imaging. The WGI has high potential to detect the location of 10C, which emits positrons with a simultaneous gamma ray of 718 keV, within the patient’s body during ion therapy. Approach. In this work, we focus on investigating the performance of WGI for 10C imaging and its feasibility for range verification in carbon ion therapy. First, the performance of the WGI was studied to image a 10C point source using the Geant4 toolkit. Then, the feasibility of WGI was investigated for an irradiated polymethyl methacrylate (PMMA) phantom with a 10C ion beam at the carbon therapy facility of the Heavy Ion Medical Accelerator in Chiba. Main results. The average spatial resolution and sensitivity for the simulated 10C point source at the centre of the field of view were 5.5 mm FWHM and 0.010%, respectively. The depth dose of the 10C ion beam was measured, and the triple gamma image of 10C nuclides for an irradiated PMMA phantom was obtained by applying a simple back projection to the detected triple gammas. Significance. The shift between Bragg peak position and position of the peak of the triple gamma image in an irradiated PMMA phantom was 2.8 ± 0.8 mm, which demonstrates the capability of triple gamma imaging using WGI for range verification of 10C ion beams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.