Hypothesis: Despite the complete embodiment of the stapedius muscle (SM) into the pyramidal eminence, it is possible to safely gain access to the SM belly via a retrofacial approach. This presents a novel approach to directly measure the electrically evoked stapedius reflex threshold (eSRT). Background: Objective fitting of maximum comfortable loudness levels for cochlear implant users can improve the benefit introduced by the device. Sensing SM activity via direct surgical access represents a potential tool for objective eSRT fitting. Methods: Eighteen human temporal bones (TBs) were used. Micro-computed tomography was performed for six TBs. Standard computed tomography for six TBs. Manual 3Dsegmentation of the relevant middle and inner ear anatomy was performed on 12 TBs. Mastoidectomy and posterior tympanotomy allowed the access to middle ear of all 18 the TBs. Once identified the mastoidal segment of the facial nerve (FN), the retrofacial access to the SM was drilled.Results: The total access rate was 72.2%. Only in the first three cases the posterior semi-circular canal was hit. The SM access was identified posterior to the FN at a 4 AE 0.78 mm distance from the stapes' head, almost halfway to the chorda tympani's branching point along the FN direction. The drilling depth to access the SM posterior to the external surface of FN on average was 2 AE 0.30 mm. The exposure took on average of 5 to 8 minutes. Conclusions: The retrofacial approach seems to offer a feasible and reproducible access to the SM belly opening an avenue to electromyographic sensing of eSRT.
The Hearing Contact Lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a Laser-Doppler-Vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a deeper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.
Human stapedius muscle (SM) can be directly and safely accessed via retrofacial approach, opening new approaches to directly measure the electrically evoked stapedius reflex threshold (eSRT). The measurement of the SM activity via direct surgical access represents a potential tool for objective eSRT fitting of cochlear implants (CI), increasing the benefit experienced by the CI users and leading to new perspectives in the development of smart implantable neurostimulators. 3D middle-ear reconstructions created after manual segmentation and related SM accessibility metrics were evaluated before the CI surgery for 16 candidates with assessed stapedius reflex. Retrofacial approach to access the SM was performed after facial recess exposure. In cases of poor exposition of SM, the access was performed anteriorly to the FN via drilling of the pyramidal eminence (PE). The total access rate of the SM via both the retrofacial and anterior approach of the FN was 100%. In 81.2% of cases (13/16), the retrofacial approach allowed to access the SM on previously categorized well exposed (8/8), partially exposed (4/5), and wholly concealed (1/3) SM with respect to FN. Following intraoperative evaluation in the remaining 18.8% (3/16), the SM was accessed anteriorly via drilling of the PE. Exposure of SM with respect to the FN and the sigmoid sinus’s prominence was a predictor for the suitable surgical approach. The retrofacial approach offers feasible and reproducible access to the SM belly, opening direct access to electromyographic sensing of the eSRT. Surgical planner tools can quantitatively assist pre-surgical assessment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.