Sodium magnetic resonance imaging (²³Na MRI) is a non-invasive technique which allows spatial resolution of the tissue sodium concentration (TSC) in the human body. TSC measurements could potentially serve to monitor early treatment success of chemotherapy on patients who suffer from whole body metastases. Yet, the acquisition of whole body sodium (²³Na) images has been hampered so far by the lack of large resonators and the extremely low signal-to-noise ratio (SNR) achieved with existing resonator systems. In this study, a ²³Na resonator was constructed for whole body ²³Na MRI at 3T comprising of a 16-leg, asymmetrical birdcage structure with 34 cm height, 47.5 cm width and 50 cm length. The resonator was driven in quadrature mode and could be used either as a transceiver resonator or, since active decoupling was included, as a transmit-only resonator in conjunction with a receive-only (RO) surface resonator. The relative B₁-field profile was simulated and measured on phantoms, and 3D whole body ²³Na MRI data of a healthy male volunteer were acquired in five segments with a nominal isotropic resolution of (6 × 6 × 6) mm³ and a 10 min acquisition time per scan. The measured SNR values in the ²³Na-MR images varied from 9 ± 2 in calf muscle, 15 ± 2 in brain tissue, 23 ± 2 in the prostate and up to 42 ± 5 in the vertebral discs. Arms, legs, knees and hands could also be resolved with applied resonator and short time-to-echo (TE) (0.5 ms) radial sequence. Up to fivefold SNR improvement was achieved through combining the birdcage with local RO surface coil. In conclusion, ²³Na MRI of the entire human body provides sub-cm spatial resolution, which allows resolution of all major human body parts with a scan time of less than 60 min.
The gene expressing the FK506 binding protein 51 (FKBP5) is involved in the regulation of glucocorticoid receptor sensitivity. The rs1360780 SNP in this gene (T allele vs C homozygous) has been found to be associated with major depressive disorder (MDD). The aim of our study was to investigate whether this polymorphism might be associated with altered brain structure and function in a cohort of 40 patients with MDD and 43 healthy controls. A functional magnetic resonance imaging (fMRI) emotional attention task was employed. Diffusion tensor imaging (DTI) was also conducted, extracting mean diffusivity (MD) and fractional anisotropy (FA) from brain areas that showed functional differences between patients expressing the two alleles of the rs1360780 SNP. Finally, the effect of the interaction of childhood adversity as measured by the Childhood trauma Questionnaire (CTQ) and rs1360780 allele status was analyzed in relation to DTI measures using a general linear model. All results presented are family-wise error (FWE) corrected. Functional interactions were found between genotype and diagnosis (po0.01). Patients carrying the high-risk allele, compared with patients not carrying it, showed reduced activity in the rolandic operculum, Heschl gyrus, insula, parahippocampal gyrus, posterior cingulate cortex, inferior frontal gyrus (po0.05 for all measures); and increased MD and reduced FA measures in many of these regions (po0.05). An interaction between CTQ scores and allele status was associated with DTI changes in the insula, rolandic operculum, and inferior frontal gyrus. Here, the presence of both the high-risk allele and higher CTQ scores was associated with higher MD and lower FA values (po0.05). In conclusion, MDD patients expressing the T allele of rs1360780, compared with C homozygous patients, exhibit functional and structural differences in areas involved in emotional perception and inhibition. The interaction between the T allele and childhood maltreatment explained our structural findings in these regions, suggesting that their altered maturation and function might be influenced by early chronic stress in the presence of this genetic trait.
A technique for noninvasively quantifying the concentration of sodium (23Na) ions was applied to the study of ischemic stroke. 23Na‐magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor signal/noise ratio. In this study, accurate quantification of tissue sodium concentration (TSC) was achieved in 23Na images with voxel sizes of 1.2 μL acquired in 10 min. The evolution of TSC was investigated from 0.5 to 8 h in focal cortical and subcortical ischemic tissue following permanent middle cerebral artery occlusion in the rat (n = 5). Infarct volumes determined from TSC measurements correlated significantly with histology (P = 0.0006). A delayed linear model was fitted to the TSC time course data in each voxel, which revealed that the TSC increase was more immediate (0.2 ± 0.1 h delay time) in subcortical ischemic tissue, whereas it was delayed by 1.6 ± 0.5 h in ischemic cortex (P = 0.0002). No significant differences (P = 0.5) were measured between TSC slope rates in cortical (10.2 ± 1.1 mM/h) and subcortical (9.7 ± 1.1 mM/h) ischemic tissue. The data suggest that any TSC increase measured in ischemic tissue indicates infarction (core) and regions exhibiting a delay to TSC increase indicate potentially salvageable tissue (penumbra). Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Abbreviations MRImagnetic resonance imaging SNR signal-to-noise ratio AbstractA method for quantifying the Tissue Sodium Concentration (TSC) in the rat brain from 23 Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study;however, its accurate measurement in small laboratory animals has been hindered by the extremely low signal to noise ratio (SNR) in 23 Na images. To address this, the design, construction and characterisation of a double-tuned 1 H/ 23 Na dual resonator system for 1 H-guided quantitative 23 Na-MRI is described. This system comprised of an SNR-optimised surface detector coil for 23 Na image acquisition, and a volume resonator producing a highly-homogeneous B 1 field (<5% inhomogeneity) for the Na channel across the rat head. The resonators incorporated channel-independent balanced matching and tuning capabilities with active decoupling circuitry at the 23 Na resonance frequency. A quantification accuracy of TSC of < 10mM was achieved in Na-images with 1.2µl voxel resolution acquired in 10 minutes. The potential of the quantification technique was demonstrated in an in vivo experiment of a rat model of cerebral stroke, where the evolution of the TSC was successfully monitored for 8 hours after the stroke was induced.
MRI and MRS in small rodents demand very high sensitivity. Cryogenic transmit/receive radiofrequency probes (CryoProbes) designed for (1) H MRI of mouse brain provide an attractive option for increasing the performance of small-animal MR systems. As the Larmor frequency of (13) C nuclei is four times lower than that for (1) H nuclei, an even larger sensitivity improvement is expected for (13) C applications. The aim of this work was to evaluate the performance of a prototype (13) C CryoProbe™ for mouse brain MRS. To investigate the possible gain of the (13) C CryoProbe™, we acquired localized single-voxel (13) C spectra and chemical shift images of a dimethyl sulfoxide phantom with the CryoProbe™, as well as with two room temperature resonators. The cryogenically cooled resonator achieved approximately four-fold higher signal-to-noise ratio in phantom tests when compared with the best-performing room temperature coil. In addition, we present localized (13) C spectra of mouse brain obtained with the CryoProbe™, as well as with one of the room temperature coils, demonstrating the performance in vivo. In summary, the cryogenic cooling technique significantly enhances the (13) C signal sensitivity at 9.4 T and enables the investigation of metabolism within mouse brain.
Tissue sodium concentration increases in irreversibly damaged (core) tissue following ischemic stroke and can potentially help to differentiate the core from the adjacent hypoperfused but viable penumbra. To test this, multinuclear hydrogen-1/sodium-23 magnetic resonance imaging (MRI) was used to measure the changing sodium signal and hydrogen-apparent diffusion coefficient (ADC) in the ischemic core and penumbra after rat middle cerebral artery occlusion (MCAO). Penumbra and core were defined from perfusion imaging and histologically defined irreversibly damaged tissue. The sodium signal in the core increased linearly with time, whereas the ADC rapidly decreased by 430% within 20 minutes of stroke onset, with very little change thereafter (0.5-6 hours after MCAO). Previous reports suggest that the time point at which tissue sodium signal starts to rise above normal (onset of elevated tissue sodium, OETS) represents stroke onset time (SOT). However, extrapolating core data back in time resulted in a delay of 72 ± 24 minutes in OETS compared with actual SOT. At the OETS in the core, penumbra sodium signal was significantly decreased (88 ± 6%, P = 0.0008), whereas penumbra ADC was not significantly different (92 ± 18%, P = 0.2) from contralateral tissue.In conclusion, reduced sodium-MRI signal may serve as a viability marker for penumbra detection and can complement hydrogen ADC and perfusion MRI in the time-independent assessment of tissue fate in acute stroke patients.
IntroductionThe purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation.MethodsElectromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated.ResultsOur simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit.ConclusionPursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants.
A double-tuned ²³Na/¹H resonator system was developed to record multinuclear MR image data during and after transient cerebral ischemia. ¹H-diffusion-, (¹H perfusion, ¹H T₂-, ¹H arterial blood flow- and ²³Na spin density-weighted images were then acquired at three time points in a rodent stroke model: (I) during 90 min artery occlusion, (II) directly after arterial reperfusion and (III) one day after arterial reperfusion. Normal ²³Na was detected in hypoperfused stroke tissue which exhibited a low ¹H apparent diffusion coefficient (ADC) and no changes in ¹H T₂ relaxation time during transient ischemia, while ²³Na increased and ADC values recovered to normal values directly after arterial reperfusion. For the first time, a similar imaging protocol was set-up on a clinical 3T MRI site in conjunction with a commercial double-tuned ¹H/²³Na birdcage resonator avoiding a time-consuming exchange of resonators or MRI systems. Multinuclear ²³Na/¹H MRI data sets were obtained from one stroke patient during both the acute and non-acute stroke phases with an aquisition time of 22 min. The lesion exhibiting low ADC was found to be larger compared to the lesion with high ²³Na at 9 h after symptom onset. It is hoped that the presented pilot data demonstrate that fast multinuclear ²³Na/¹H MRI preclinical and clinical protocols can enable a better understanding of how temporal and regional MRI parameter changes link to pathophysiological variations in ischemic stroke tissue.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.