Sudden cardiac death (SCD) remains a daunting problem. It is a major public health issue for several reasons: from its prevalence (20% of total mortality in the industrialized world) to the devastating psycho-social impact on society and on the families of victims often still in their prime, and it represents a challenge for medicine, and especially for cardiology. This text summarizes the discussions and opinions of a group of investigators with a long-standing interest in this field. We addressed the occurrence of SCD in individuals apparently healthy, in patients with heart disease and mild or severe cardiac dysfunction, and in those with genetically based arrhythmic diseases. Recognizing the need for more accurate registries of the global and regional distribution of SCD in these different categories, we focused on the assessment of risk for SCD in these four groups, looking at the significance of alterations in cardiac function, of signs of electrical instability identified by ECG abnormalities or by autonomic tests, and of the progressive impact of genetic screening. Special attention was given to the identification of areas of research more or less likely to provide useful information, and thereby more or less suitable for the investment of time and of research funds.
on behalf of the European 7219 Jewel ICD InvestigatorsBackground-A newly developed classification system relates adverse events to the surgical procedure or the function of the implantable defibrillator. Methods and Results-Adverse events were monitored during prospective clinical evaluation of the Medtronic model 7219Jewel ICD and were classified according to the definitions of the ISO 14155 standard for device clinical trials into 3 groups: severe and mild device-related and severe non-device-related adverse events. In addition, events were related to the surgical procedure, treatment with the device, or cardiac function. Seven hundred seventy-eight patients were followed up for an average of 4.0 months after ICD implantation. In total, 356 adverse events were observed in 259 patients. At 1, 3, and 12 months after ICD implantation, 99%, 98%, and 97% of the patients, respectively, survived; 95%, 93%, and 92%, respectively, were free of surgical reintervention; and 79%, 68%, and 51%, respectively, were free of any adverse event. Twenty patients died: 6 deaths were related to the surgical procedure, 12 deaths were considered unrelated to ICD treatment, and 2 patients died of an unknown cause. Of 111 nonlethal severe adverse device effects, 47 required surgical intervention, 19 times for correction of a dislodged lead. Inappropriate delivery of therapy was observed 128 times in 111 patients, and the events were typically resolved by reprogramming or drug adjustment. Nine of these required rehospitalization. Conclusions-Approximately 50% of patients experience an adverse event within the first year after ICD implantation.The observed adverse event rate depends on the definitions and the prospective monitoring. The incidence of inappropriate therapy emphasizes the need for improved detection algorithms and for quality-of-life evaluations, especially when considering ICD treatment in high-risk but arrhythmia-free patients. (Circulation. 1998;98:663-670.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.