Allergen extracts have been used for diagnosis and treatment of allergy for around 100 years. During the second half of 20th century, the notion increasingly gained foothold that accurate standardization of such extracts is of great importance for improvement of their quality. As a consequence, manufacturers have implemented extensive protocols for standardization and quality control. These protocols have overall IgE-binding potencies as their focus. Unfortunately, each company is using their own in-house reference materials and their own unique units to express potencies. This does not facilitate comparison of different products. During the last decades, most major allergens of relevant allergen sources have been identified and it has been established that effective immunotherapy requires certain minimum quantities of these allergens to be present in the administered maintenance dose. Therefore, the idea developed to introduce major allergens measurements into standardization protocols. Such protocols based on mass units of major allergen, quantify the active ingredients of the treatment and will at the same time allow comparison of competitor products. In 2001, an EU funded project, the CREATE project, was started to support introduction of major allergen based standardization. The aim of the project was to evaluate the use of recombinant allergens as reference materials and of ELISA assays for major allergen measurements. This paper gives an overview of the achievements of the CREATE project.
Chimeric-antigen-receptor (CAR)-T-cell therapy is already widely used to treat patients who are relapsed or refractory to chemotherapy, antibodies, or stem-cell transplantation. Multiple myeloma still constitutes an incurable disease. CAR-T-cell therapy that targets BCMA (B-cell maturation antigen) is currently revolutionizing the treatment of those patients. To monitor and improve treatment outcomes, methods to detect CAR-T cells in human peripheral blood are highly desirable. In this study, three different detection reagents for staining BCMA-CAR-T cells by flow cytometry were compared. Moreover, a quantitative polymerase chain reaction (qPCR) to detect BCMA-CAR-T cells was established. By applying a cell-titration experiment of BCMA-CAR-T cells, both methods were compared head-to-head. In flow-cytometric analysis, the detection reagents used in this study could all detect BCMA-CAR-T cells at a similar level. The results of false-positive background staining differed as follows (standard deviation): the BCMA-detection reagent used on the control revealed a background staining of 0.04% (±0.02%), for the PE-labeled human BCMA peptide it was 0.25% (±0.06%) and for the polyclonal anti-human IgG antibody it was 7.2% (±9.2%). The ability to detect BCMA-CAR-T cells down to a concentration of 0.4% was similar for qPCR and flow cytometry. The qPCR could detect even lower concentrations (0.02–0.01%). In summary, BCMA-CAR-T-cell monitoring can be reliably performed by both flow cytometry and qPCR. In flow cytometry, reagents with low background staining should be preferred.
Im Gegensatz zum Menschen, bei dem ein erworbener portosystemischer Shunt meist nur sekund?r durch
Erkrankungen der Leber auftritt, kommt der portosystemische Shunt beim Hund ?fter angeboren als erworben
vor. Die H?ufigkeit der Erkrankung wird kritisch diskutiert. Man geht jedoch von einer erheblichen
Dunkelziffer aus, insbesondere weil die Symptome mannigfaltig sind und die Auspr?gung sehr
unterschiedlich ist. Die Erkrankung z?hlt zu den beim Hund beschriebenen Erbkrankheiten.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.