A laser-based ethylene detector was used for on-line monitoring of ethylene released by the phytopathogenic fungus Botrytis cinerea in vitro and in tomato fruit. Ethylene data were combined with the results of a cytological analysis of germination of B. cinerea conidia and hyphal growth. We found that aminoethoxyvinylglycine and aminooxyacetic acid, which are competitive inhibitors of the 1-aminocyclopropane-1-carboxylic acid pathway, did not inhibit the ethylene emission by B. cinerea and that the fungus most likely produces ethylene via the 2-keto-4-methylthiobutyric acid pathway. B. cinerea is able to produce ethylene in vitro, and the emission of ethylene follows the pattern that is associated with hyphal growth rather than the germination of conidia. Ethylene production in vitro depended on the L-methionine concentration added to the plating medium. Higher values and higher emission rates were observed when the concentration of conidia was increased. Compared with the ethylene released by the fungus, the infection-related ethylene produced by two tomato cultivars (cultivars Money Maker and Daniela) followed a similar pattern, but the levels of emission were 100-fold higher. The time evolution of enhanced ethylene production by the infected tomatoes and the cytological observations indicate that ethylene emission by the tomato-fungus system is not triggered by the ethylene produced by B. cinerea, although it is strongly synchronized with the growth rate of the fungus inside the tomato.
Dual-comb spectroscopy can provide broad spectral bandwidth and high spectral resolution in a short acquisition time, enabling time-resolved measurements. Specifically, spectroscopy in the mid-infrared wavelength range is of particular interest, since most of the molecules have their strongest rotational-vibrational transitions in this “fingerprint” region. Here we report time-resolved mid-infrared dual-comb spectroscopy, covering ~300 nm bandwidth around 3.3 μm with 6 GHz spectral resolution and 20 μs temporal resolution. As a demonstration, we study a CH4/He gas mixture in an electric discharge, while the discharge is modulated between dark and glow regimes. We simultaneously monitor the production of C2H6 and the vibrational excitation of CH4 molecules, observing the dynamics of both processes. This approach to broadband, high-resolution, and time-resolved mid-infrared spectroscopy provides a new tool for monitoring the kinetics of fast chemical reactions, with potential applications in various fields such as physical chemistry and plasma/combustion analysis.
Since ancient times people have searched for ways to understand processes occurring in the environment, atmosphere or living organisms. Study of the gaseous trace compounds present may shed new light on chemical reactions taking place in the atmosphere or biochemical reactions inside organisms such as plants, animals and human beings. This article presents photoacoustic spectroscopy as a sensitive, on‐line and noninvasive tool for monitoring the concentration of trace gases. Following a short introduction and a historic overview, attention is focused on the description of devices and equipment which determine the detection limits and selectivity. An overview is given of the current detection limits for photoacoustic detection. Applications are discussed with emphasis on environmental monitoring (in ambient air, car exhaust and stack gas emission), on medical applications and on biological applications (in postharvest physiology, plant physiology, microbiology and entomology).
Fractional exhaled nitric oxide (F(E)NO) is considered an indicator in the diagnostics and management of asthma. In this study we present a laser-based sensor for measuring F(E)NO. It consists of a quantum cascade laser (QCL) combined with a multi-pass cell and wavelength modulation spectroscopy for the detection of NO at the sub-part-per-billion by volume (ppbv, 110(-9)) level. The characteristics and diagnostic performance of the sensor were assessed. A detection limit of 0.5 ppbv was demonstrated with a relatively simple design. The QCL-based sensor was compared with two market sensors, a chemiluminescent analyzer (NOA 280, Sievers) and a portable hand-held electrochemical analyzer (MINO, Aerocrine AB, Sweden). F(E)NO from 20 children diagnosed with asthma and treated with inhaled corticosteroids were measured. Data were found to be clinically acceptable within 1.1 ppbv between the QCL-based sensor and chemiluminescent sensor and within 1.7 ppbv when compared to the electrochemical sensor. The QCL-based sensor was tested on healthy subjects at various expiratory flow rates for both online and offline sampling procedures. The extended NO parameters, i.e. the alveolar region, airway wall, diffusing capacity, and flux were calculated and showed a good agreement with the previously reported values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.