Aspirated blood contaminated by tissue contact is the most important activator of the coagulation system and the principal cause of hemolysis during cardiopulmonary bypass. Contact with a foreign surface is not a main variable in the procoagulant effect of bypass. Mimicking the outer cell membrane structure resulted in decreased platelet activation and decreased blood loss.
A series of 146 consecutive patients who underwent tricuspid valve replacement at the University Brugmann Hospital between 1967 and 1987 was reviewed. Mean age at operation was 51.4 years (+/- 12.1 years). Different types of prostheses were implanted including porcine and bovine pericardial bioprostheses and older and bileaflet mechanical valves. Most patients were severely disabled by their cardiac disease before operation, with 30.1% in New York Heart Association functional class III and 69.9% in class IV. Operative mortality and hospital mortality rates (30 days) were high (16.4%). Incremental risk factors for hospital death included icterus (p < 0.005), preoperative hepatomegaly (p = 0.012), and New York Heart Association functional class IV (p = 0.013). Multivariate analysis only selected preoperative icterus (p < 0.01) as being independently significantly related to hospital mortality. The hospital survivors were followed up for a median of 94 months. A complete follow-up was available for all patients except two for 30 months or more. At 30 months the only two significant parameters were the type of myocardial protection (p = 0.024) and the year of operation (before 1977 or after [precardioplegia era or after], p = 0.011). There were 70 late deaths during the entire follow-up period. The univariate (log-rank statistics) incremental risk factor for late death was the type of tricuspid prosthesis (Smeloff-Cutter and Kay-Shiley versus St. Jude Medical versus bioprosthesis) (p = 0.04). A trend was observed for the type of operative myocardial protection (normothermia and coronary perfusion) (p = 0.06) and preoperative New York Heart Association functional class IV (p = 0.055). Actuarial survival was 74% at 60 months and 23.4% at 180 months. Cumulative follow-up added up to 1015 patient-years. In a more detailed analysis of the effect on survival of the type of tricuspid prosthesis, a significant difference was observed between the bioprostheses and some older mechanical prostheses (Smeloff-Cutter and Kay-Shiley) (p = 0.04) but not between the bioprostheses and the bileaflet valves (p = 0.15). When the follow-up period was stratified according to less than 7 years and more than 7 years of follow-up, no difference was observed for the first period, but for the late follow-up the new mechanical prostheses did better than the bioprostheses (p = 0.05), suggesting a degradation of the bioprostheses after 7 years and favoring mechanical prostheses for those patients with a good long-term prognosis.
Coronary bypass surgery with and without extracorporeal circulation results in dramatic impairment of respiratory system mechanics. Based on respiratory system mechanics, early extubation after coronary artery bypass grafting should be performed with caution, no matter whether the off-pump or cardiopulmonary bypass technique is used.
Return of blood activated by tissue factor is the main culprit for triggering the coagulation cascade. When this activated blood is diverted from the cardiopulmonary bypass (CPB) circuit, it becomes possible to evaluate the effect of surface treatment on platelet and complement activation. Twenty adult patients undergoing elective coronary artery bypass grafting (CABG) were randomly assigned either to a control group (n=10) or to a group in which the CPB circuit was completely coated with phosphorylcholine (n=10). Plasma concentrations of platelet factor 4 (PF4), beta-thromboglobulin (betaTG), C3, C3d, C4, TCC, thrombin generation, haptoglobin and free haemoglobin, as well as blood loss, were measured. No significant differences between the two groups were found for haemolysis and thrombin generation. The mean total release of PF4 and betaTG during CPB was 9338+/-17303 IU/ml/CPB and 3790+/-4104 IU/ml/CPB in the coated group versus 22192+/-13931 IU/ml/CPB (p=0.011) and 8040+/-3986 IU/ml/CPB (p=0.005) in the control group. Blood loss was 30% less in the coated group compared to the control group. Phosphorylcholine coating appears to have a favourable effect on blood platelets, which is most obvious after studying the changes during CPB. Clinically, this effect resulted in a 30% reduction in blood loss.
SVR in addition to coronary revascularization and restrictive mitral annuloplasty results in significant clinical improvement in selected patients with advanced ischemic heart disease and severely dilated ventricles. SVR entails immediate improvement of systolic function, which remains sustained during short-term follow-up. Serial assessment of diastolic function is mandatory as LV compliance seems more sensitive to early changes induced by recurrence of mitral regurgitation and secondary ventricular dilation. Moreover, worsening of diastolic dysfunction should be timely recognized because of its adverse clinical impact.
Although the implantation technique is much more demanding for stentless procedures, reflected by a longer aortic clamp-time, and remains impossible in some cases, elderly, small sized patients take full benefit of their large, non-obstructive prostheses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.