Background New intraocular lenses (IOLs) have emerged since the originally coined monofocal and multifocal IOLs. The extended depth of focus (EDoF) and enhanced monofocal IOLs (mono-EDoF) that have appeared in the last decade have caused some confusion in their classification. The aim of this review was to summarize the outcomes provided by mono-EDOF IOLs and to determine which of the endpoints, described by the American National Standard (ANSI) for EDoF IOLs, are fulfilled. Methods The MEDLINE, EMBASE, and WEB OF SCIENCE databases were searched. Two independent reviewers screened the studies for inclusion and data extraction. The search strategy was limited to studies published between 2020 and 2022, but not by language. The results are presented as a narrative summary accompanied by tables, in alignment with the objectives of this scoping review. Compliance with the endpoints for clinical outcomes described in the American National Standard Z80.35–2018 (ANSI) for EDoF lenses was checked and additional endpoints were defined. Results Two systematic reviews, 13 laboratory, 21 clinical, and two mixed studies were included. Tecnis Eyhance was the mono-EDOF with the highest volume of evidence to date. Although laboratory studies included other IOLs, clinical evidence for them is still scarce, with only one study of IsoPure compared to a standard monofocal IOL. Evidence in comparison to EDoF lenses is also scarce, even for Tecnis Eyhance, with only three studies including this lens in comparison to an EDoF lens. After evaluation of the ANSI criteria, agreement was found in the failure for the increase in depth of field equal to or greater than 0.5 D for a visual acuity (VA) level of 0.2 logMAR and none of the studies supported that the median monocular VA at intermediate distance was at least 0.2 logMAR. Conclusions Additional clinical evidence is required for other mono-EDOF IOLs beyond Tecnis Eyhance. Until the arrival of a standard classification, mono-EDOF should be better still classified as monofocal because the ANSI standards were not fully met.
Purpose To evaluate the microbiota of culture negative Corneal Impression Membrane (CIM) microbial keratitis samples with the use of shotgun metagenomics analysis. Methods DNA of microbial keratitis samples were collected with CIM and extracted using the MasterPure™ Complete DNA and RNA Purification Kit (Epicentre). DNA was fragmented by sonication into fragments of 300 to 400 base pairs (bp) using Bioruptor® (Diagenode, Belgium) and then used as a template for library preparation. DNA libraries were sequenced on Illumina® HiSeq2500. The resulting reads were quality controlled, trimmed and mapped against the human reference genome. The unmapped reads were taxonomically classified using the Kraken software. Results 18 microbial keratitis samples were included in the study. Brevundimonas diminuta was found in 5 samples while 6 samples showed the presence of viral infections. Cutibacterium acnes, Staphylococcus aureus, Moraxella lacunata and Pseudomonas alcaligenes were also identified as the presumed putative cause of the infection in 7 samples. Conclusions Shotgun sequencing can be used as a diagnostic tool in microbial keratitis samples. This diagnostic method expands the available tests to diagnose eye infections and could be clinically significant in culture negative samples.
To measure the effects of Autologous serum (AS), Allogeneic Serum (HS) and Umbilical Cord serum (CS) eye drops in severe dry eye disease (DES), as well as to characterize and quantify several molecules in the three sera (albumin, fibronectin; Vitamin A and E; IgG, IgA and IgM; Transforming growth factor β; Epithelial growth factor).Methods: Randomized, double-blind, single-centre, three-arm (AS, HS and CS) clinical trial. Sixty-three subjects were included with severe DES, 21 in each arm of the study. Visual acuity, Schirmer test, Breakup time (BUT), lissamine green, fluorescein staining measurements and a questionnaire were performed prior to treatment, and after one-month and three-month follow-up.Results: There was a significant main effect of time on visual acuities, Schirmer and BUT tests and fluorescein and lissamine green staining measurements and questionnaire scores (p = 0.015, p = 0.002, p < 0.001, p < 0.001, p = 0.031 and p < 0.001, respectively), although there was no significant interaction between time and serum type, nor between serum type and the test performed. Regarding the concentration of molecules, in our study AS contained significantly higher concentrations of IgA, IgG and fibronectin whereas HS contained significantly higher concentration of IgM, vitamins A and E, TGF and albumin. Contrary to previous reports, CS did not show higher concentration of any of the molecules analysed. Conclusions and relevance:The three sera were effective in the treatment of severe DES. CS did not contain a higher proportion of molecules compared to AS/HS. More research is needed to assess the effect of AS in patients with DES and autoimmune diseases.
PURPOSE: To conduct a critical review of the peer-reviewed literature on the use of supplemental multifocal intraocular lenses in the ciliary sulcus. METHODS: This systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement recommendations. According to the inclusion and exclusion criteria defined, 15 articles were selected for the current systematic review. Each of them was analyzed carefully and their risk of bias was assessed with the Quality Assessment Tool for Case Series Studies from the National Heart, Lung, and Blood Institute. RESULTS: Data of 384 eyes from 227 patients were analyzed. Most of the studies reviewed had a short follow-up and poor or limited design, including case reports, case series, and clinical trials with several gaps in their methodology. Post-operative uncorrected distance and near visual acuity ranged from 20/40 to 20/20 and from 0.4 to 0.02 logMAR, respectively. Pigment dispersion (12 eyes) and deposits (13 eyes) were the most described complication. Dysphotopsia, glare, and halos were the more frequently reported visual disturbances. However, most of the patients reported a high level of satisfaction with their surgery. Most articles reviewed (13 of 15) achieved a risk of bias score between 6 and 8, representing a high level of evidence despite the study design limitations. CONCLUSIONS: Supplemental multifocal intraocular lenses seem to offer good distance and near visual results, leading to high levels of spectacle independence and patients' satisfaction, with limited complications associated. However, more studies with a more robust design are needed to confirm these trends. [ J Refract Surg . 2021;37(12):830–835.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.