Purpose To analyse the impact of prolonged mandatory lockdown due to COVID-19 on hip fracture epidemiology. Methods Retrospective case-control study of 160 hip fractures operated upon between December 2019 and May 2020. Based on the date of declaration of national lockdown, the cohort was separated into two groups: 'pre-COVID time' (PCT), including 86 patients, and 'COVID time' (CT), consisting of 74 patients. All CT patients tested negative for SARS-CoV-2. Patients were stratified based on demographic characteristics. Outcome measures were 30-day complications, readmissions and mortality. A logistic regression model was run to evaluate factors associated with mortality. Results Age, female/male ratio, body mass index and American Society of Anaesthesia score were similar between both groups (p > 0.05). CT patients had a higher percentage of Charlson ≥ 5 and Rockwood Frailty Index ≥ 5 scores (p < 0.05) as well as lower UCLA and Instrumental Activities of Daily Living scores (p < 0.05). This translated into a higher hemiarthroplasty/total hip arthroplasty ratio during CT (p = 0.04). Thromboembolic disease was higher during CT (p = 0.02). Readmissions (all negative for SARS-CoV-2) were similar between both groups (p = 0.34). Eight (10.8%) casualties were detected in the CT group, whereas no deaths were seen in the control group. Logistic regression showed that frailer (p = 0.006, OR 10.46, 95%CI 8.95-16.1), less active (p = 0.018, OR 2.45, 95%CI 1.45-2.72) and those with a thromboembolic event (p = 0.005, OR 30, 95%CI 11-42) had a higher risk of mortality.
Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplemented impacted bone allografts and a standard, cemented Charnley femoral component. The mean follow-up was 32.4 months (24 to 60). Infection control was obtained in 29 cases (re-infection rate of 3.3%; 95% confidence interval 0.08 to 17) without evidence of progressive radiolucent lines, demarcation or graft resorption. One patient had a further infection ten months after revision caused by a different pathogen. Associated post-operative complications were one traumatic periprosthetic fracture at 14 months, a single dislocation in two hips and four displacements of the greater trochanter. Vancomycin-supplemented allografts restored bone stock and provided sound fixation with a low incidence of further infection.
Local levels of vancomycin were 35 times greater than the highest levels reported with vancomycin-loaded PMMA. A synergistic effect was observed between vancomycin released from impacted allografts and aminoglycoside-loaded PMMA.
Background The sensitivity and specificity to detect periprosthetic infection of the different methods have been questioned, and no single laboratory test accurately detects infection before revision arthroplasty. Questions/purposes We asked whether preoperative C-reactive protein (CRP) and interleukin-6 (IL-6) could lead to similar sensitivity, specificity, and predictive values as our previous results obtained with intraoperative frozen section (FS) in revision total hip arthroplasty (THA). Methods We prospectively followed 69 patients who had undergone revision THA for failure of a primary THA. The definitive diagnosis of an infection was determined on the basis of positive histopathologic evidence of infection or growth of bacteria on culture.
We reviewed the clinical and radiological results of 131 patients who underwent acetabular revision for aseptic loosening with impacted bone allograft and a cemented acetabular component. The mean follow-up was 51.7 months (24 to 156). The mean post-operative Merle D'Aubigné and Postel scores were 5.7 points (4 to 6) for pain, 5.2 (3 to 6) for gait and 4.5 (2 to 6) for mobility. Radiological evaluation revealed migration greater than 5 mm in four acetabular components. Radiological failure matched clinical failure. Asymptomatic radiolucent lines were observed in 31 of 426 areas assessed (7%). Further revision was required in six patients (4.5%), this was due to infection in three and mechanical failure in three. The survival rate for the reconstruction was 95.8% (95% confidence interval 92.3 to 99.1) overall, and 98%, excluding revision due to sepsis. Our study, from an independent centre, has reproduced the results of the originators of the method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.