Polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) may enter an incinerator with the waste, be created in poor combustion or form in post-combustion zones under certain conditions of temperature and oxygen. Tests of MSW burning plants show a wide range of emissions of PCDD and PCDF. Diagnostic tests show the relationship between combustion conditions and the emission of PCDD/DF before and after emission controls. Mixing effectiveness, tightness of control, moisture, furnace and post-furnace temperatures, and the use of lime and reduced temperatures for acid-gas control all have an effect on emissions of trace organics. Carbon monoxide (CO), oxygen, moisture and furnace temperature have been found to be closely related to PCDD/PCDF emissions. By control of temperature and/or oxygen, and the use of CO as an indicator, it is possible to find and maintain optimum combustion conditions so as to minimize dioxins and furans. Plants having acid-gas controls reduce emissions below those achieved by good combustion alone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.