Purpose To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP. Methods This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automatedendothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland-Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP.Results iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, Po0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of À6.5 ± 1.9 mm Hg, Po0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes. Conclusions The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.
HRT II Rostock Corneal Module and the Tomey EM-3000 showed an overall good intermethod agreement. HRT showed a tendency to slightly overestimate CCT measurements, significantly underestimate ECD measurements in eyes with a reduced cell density (< 2290 cells per square millimeter), and overestimate ECD in eyes with a high cell density. Both instruments showed low intra- and interobserver TRV for both CCT and ECD measurements, which tended to be less for Tomey.
Purpose. To assess surgical outcomes of lower lid reconstruction surgery using auricular conchal tissue. Methods. This prospective study included 20 patients that underwent reconstructive lower lid surgery using autologous auricle chondral-perichondral graft tissue. Auricle tissue was used to provide adequate support and protection with similar conjunctiva tarsal structures on overlying soft tissues in patients with pathologic inferior lid tissue loss requiring reconstructive surgery. Biopsies with histopathology and cytology analysis were taken after 1 year. Cytology analysis using CK19 was used to confirm newly formed conjunctiva overlying the graft. Results. All patients showed no graft rejection. Surgical outcomes were generally good, with minimal or no ocular complications. 16 of 20 patients had excellent results, showing good lid symmetry and esthetics, minimal auricular discomfort, patient satisfaction and proper lid function. Surgical outcomes were highly dependent on proper post-op conjunctiva formation. All patients were positive for CK19, thus indicating proper conjunctiva tissue formation. Conclusions. Lower lid reconstruction surgery using auricular chondral-perichondral conchal tissue is a good alternative in patients with neoplastic lesions. Autologous chondral-perichondral tissue provides good functional and mechanical support in the reconstructed lid, thus reducing the risks of ectropion and corneal exposure and ensuring a protected ocular surface.
The sensitivity of a new device, which is able to measure the thickness of the retina at the posterior pole (Retinal Thickness Analyzer), was assessed in a group of 21 glaucomatous patients, and in 24 patients with ocular hypertension. The specificity of RTA was evaluated in a control group of normal eyes. Of the glaucomatous eyes, 57.6% had a significant reduction in retinal thickness, while another 30.3% were borderline. In the ocular hypertension group, 37.5% of eyes were abnormal, and 45.8% were borderline. In the control group, no eye was abnormal, though 42.9% had borderline alterations. In many glaucomatous eyes (81.8%) there was a relationship between retinal thickness loss and visual field defects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.