BackgroundThe risk of radio-induced gastrointestinal (GI) complications is affected by several factors other than the dose to the rectum such as patient characteristics, hormonal or antihypertensive therapy, and acute rectal toxicity. Purpose of this work is to study clinical and dosimetric parameters impacting on late GI toxicity after prostate external beam radiotherapy (RT) and to establish multivariate normal tissue complication probability (NTCP) model for radiation-induced GI complications.MethodsA total of 57 men who had undergone definitive RT for prostate cancer were evaluated for GI events classified using the RTOG/EORTC scoring system. Their median age was 73 years (range 53–85). The patients were assessed for GI toxicity before, during, and periodically after RT completion. Several clinical variables along with rectum dose-volume parameters (Vx) were collected and their correlation to GI toxicity was analyzed by Spearman’s rank correlation coefficient (Rs). Multivariate logistic regression method using resampling techniques was applied to select model order and parameters for NTCP modeling. Model performance was evaluated through the area under the receiver operating characteristic curve (AUC).ResultsAt a median follow-up of 30 months, 37% (21/57) patients developed G1-2 acute GI events while 33% (19/57) were diagnosed with G1-2 late GI events. An NTCP model for late mild/moderate GI toxicity based on three variables including V65 (OR = 1.03), antihypertensive and/or anticoagulant (AH/AC) drugs (OR = 0.24), and acute GI toxicity (OR = 4.3) was selected as the most predictive model (Rs = 0.47, p < 0.001; AUC = 0.79). This three-variable model outperforms the logistic model based on V65 only (Rs = 0.28, p < 0.001; AUC = 0.69).ConclusionsWe propose a logistic NTCP model for late GI toxicity considering not only rectal irradiation dose but also clinical patient-specific factors. Accordingly, the risk of G1-2 late GI increases as V65 increases, it is higher for patients experiencing previous acute toxicity and it is lower for patients who take AH/AC drugs. The developed NTCP model could represent a potentially useful tool to be used in prospective trial and for comparison among different RT techniques.
In this study, the indoor radon concentrations have been measured in 93 dwellings of the Penisola Sorrentina, using LR115 detectors. The detectors were placed in the bedrooms and living rooms for two consecutive semesters starting from December 2010 to December 2011. The annual average indoor radon concentrations vary from 25 to 722 Bq m(-3), with a mean value of 132 ± 114 Bq m(-3). Correlation between indoor radon measurements and same building characteristics was also studied. Based on the obtained results, the mean annual effective dose of 2.4 mSv y(-1) received by inhabitants was estimated.
Indoor radon concentrations were measured in dwellings of the Puglia region in Southern Italy using LR-115 passive detectors. The results show that the radon concentrations varied from 15 ± 2 to 2166 ± 133 Bq/m3 with a geometric mean of 114 Bq/m3 and a geometric standard deviation of 2.3. An analysis on the factors affecting radon concentration such as age of the dwellings, floors, and stories, was performed. The mean effective dose to inhabitants has been calculated and found to be 8.2 mSv/y. Finally, for estimation of cancer risks, the lifetime risk and lung cancer cases per years per million have been calculated.
Hypofractionation for localized prostate cancer treatment is rapidly spreading in the medical community and it is supported by radiobiological evidences (lower α/β ratio compared with surrounding tissues). Stereotactic body radiation therapy (SBRT) is a technique to administer high doses with great precision, which is commonly performed with CyberKnife (CK) in prostate cancer treatment. Since the CyberKnife (CK) is not available at all radiotherapy center, alternative SBRT techniques are available such as Volumetric Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT). The aim of the present study was to compare the dosimetric differences between the CK, VMAT, and HT plans for localized prostate cancer treatment.
Seventeenpatients have been recruited and replanned using VMAT and HT to this purpose: they received the treatment using the CK with a prescription of 36.25 Gy in 5 fractions; bladder, rectum and penis bulb were considered as organs at risk (OAR). In order to compare the techniques, we considered DVHs, PTV coverage, Conformity Index and new Conformity Index, Homogeneity Index, beam-on time and OARs received dose.
The 3 treatments methods showed a comparable coverage of the lesion (PTV 95%: 99.8 ± 0.4% CK; 98.5 ± 0.8% VMAT; 99.4 ± 0.5% HT.
P
< .05) and good sparing of OARs. Nevertheless, the beam-on time showed a significant difference (37 ± 9 m CK; 7.1 ± 0.3 m VMAT; 17 ± 2 m HT.
P
< .05).
Our results showed that, although CK is the best SBRT technique for prostate cancer treatment, in case this technology is not available, it can be replaced by a similar treatment delivered by VMAT technique. VMAT can be administrated only if it has an appropriate Image Guided Radiation Therapy (IGRT) tracking system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.