BACKGROUND: Treatment of the distal tibial fractures are challenging due to the limited soft tissue, subcutaneous location and poor vascularity. In this control-matched study, it was aimed to compare the traditional open reduction and internal fixation with minimal invasive plating (MIPO). We hypothesized that superior results may be achieved with MIPO technique.
IntroductionThis study aimed to analyze the midterm outcomes of LUMiC® endoprosthetic reconstruction following periacetabular resection of primary bone sarcomas and carcinoma metastases.Patients and MethodsWe retrospectively reviewed the charts of 21 patients (11 male [52.3%], 10 female [47.6%]; mean age 47 ± 16 years) for whom a LUMiC® endoprosthesis (Implantcast) was used to reconstruct a periacetabular defect after internal hemipelvectomy. The tumor was pathologically diagnosed as Ewing's sarcoma in six (28.5%), chondrosarcoma in 10 (47.6%), and bone metastasis from carcinoma in five (23.8%) patients.ResultsThe median follow‐up of patients was 57.8 months (95% confidence interval: 51.9–63.7). The implant survival rate at 1, 2, and 5 years were 95.2%, 85.7%, and 80.9%, respectively. The overall complication rate was 33.3% (n = 7). Four (19%) complications resulted in reconstruction failure. Total reoperation rate was 28.5% (n = 6). The complications were soft tissue failure/dislocation in two patients, aseptic loosening in one, infection in two, and local recurrence in two. At the time of study, seven patients were alive with no evidence of disease, seven were alive with disease, and seven died of disease. The 5‐year overall survival rate and local recurrence‐free survival rates were 67% and 76%, respectively. The median Musculoskeletal Tumor Society score at final follow‐up was 70% (range: 50%–86.6%).ConclusionWe conclude that LUMiC® endoprosthesis provides good functional outcomes and a durable reconstruct. Even though this reconstruction method presents some complications, it provides a stable pelvis in the management of periacetabular malignant tumors.
We present the clinical results and ultrasonographic findings of 61 trigger digits treated with percutaneous A1 pulley release. An endoscopic carpal tunnel knife was used for the release in the outpatient department. The mean follow-up period was 3.5 months. A total of 55 digits (90%) had complete relief of their triggering postoperatively. Six digits (10%) had Grade 2 triggering clinically in the early postoperative period.The complications included six cases of insufficient release (10%), scar sensitivity in one patient, short-term hypoaesthesia in three digits (5%), and flexor tendon laceration noted on postoperative ultrasonography in eight digits (13%). No neurovascular damage was noted on the postoperative ultrasonography. Ultrasonograpy provides information about tendon laceration and changes in thickness of the pulleys and confirm A1 pulley release after surgery, but it does not alter clinical decision-making. We believe that pre- and postoperative ultrasonograpy does not need to be included as a routine examination.
Anterior cruciate ligament injuries are common, mostly occurring during sports trauma. Conversely, patellar tendon ruptures are uncommon injuries secondary to forceful contractions of the extensor mechanism. It is important to consider the possibility of combined injuries around the knee. We present a case of neglected patellar tendon rupture with anterior cruciate ligament and medial collateral ligament rupture treated with arthroscopic anterior cruciate ligament reconstruction combined with patellar tendon reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.