Functional threshold power is defined as the highest power output a cyclist can maintain in a quasi-steady state for approximately 60 min (FTP). In order to improve practicality for regular evaluations, FTP could theoretically be determined as 95% of the mean power output in a 20-min time trial (FTP). This study tested this assumption and the validity of FTP and FTP against the individual anaerobic threshold (IAT). Twenty-three trained male cyclists performed an incremental test to exhaustion, 20- and 60-min time trials, and a time to exhaustion at FTP. Power output, heart rate and oxygen uptake representing FTP, FTP and IAT were not different (p>0.05), and large to very large correlations were found (r=0.61 to 0.88). Bland-Altman plots between FTP, FTP and IAT showed small bias (-1 to -5 W), but large limits of agreement ([-40 to 32 W] to [-62 to 60 W]). Time to exhaustion at FTP was 50.9±15.7 min. In conclusion, FTP and FTP should not be used interchangeably on an individual basis and their validity against IAT should be interpreted with caution.
Purpose: Functional threshold power (FTP), determined as 95% of the average power during a 20-min time trial, is suggested as a practical test for the determination of the maximal lactate steady state (MLSS) in cycling. Therefore, the objective of the present study was to determine the validity of FTP in predicting MLSS. Methods: A total of 15 cyclists, 7 classified as trained and 8 as well trained (mean [SD] maximal oxygen uptake 62.3 [6.4] mL·kg−1·min−1, maximal aerobic power 329 [30] W), performed an incremental test to exhaustion, an FTP test, and several constant-load tests to determine the MLSS. The bias ± 95% limits of agreement (LoA), typical error of the estimate (TEE), and Pearson coefficient of correlation (r) were calculated to assess validity. Results: For the power-output measures, FTP presented a bias ± 95% LoA of 1.4% ± 9.2%, a moderate TEE (4.7%), and nearly perfect correlation (r = .91) with MLSS in all cyclists together. When divided by training level, the bias ± 95% LoA and TEE were higher in the trained group (1.4% ± 11.8% and 6.4%, respectively) than in the well-trained group (1.3% ± 7.4% and 3.0%, respectively). For the heart-rate measurement, FTP presented a bias ± 95% LoA of −1.4% ± 8.2%, TEE of 4.0%, and very large correlation (r = .80) with MLSS. Conclusion: Therefore, trained and well-trained cyclists can use FTP as a noninvasive and practical alternative to estimate MLSS.
Therefore, trained cyclists should develop maximal aerobic power irrespective of the duration of time trial, as well as enhancements in metabolic thresholds for long-duration time trials.
Functional threshold power (FTP) is defined as the highest power that a cyclist can maintain in a quasi-steady state without fatigue for approximately 1 hour. To improve practicality, a 20-minute time-trial test was proposed, where FTP is represented by 95% of the mean power produced. It is preceded by a specific 45-min warm-up, with periods of low intensity, fast accelerations, and a 5-min time-trial. Thus, the aim of this study was to determine the reliability of this protocol, including the reliability of the warm-up, pacing strategy, and FTP determination. For this purpose, 25 trained cyclists performed a familiarization and two other tests separated by seven days. The coefficient of variation (CV [%]), intraclass correlation coefficient (ICC), and change in the mean between test and retest were calculated. The results show that the 20-min time-trial was reliable (CV=2.9%, ICC=0.97), despite a less reliable warm-up (CV=5.5%, ICC=0.84). The changes in the mean between the test and retest were trivial to small for all measurements, and the pacing strategy was consistent across all trials. These results suggest that FTP determination with a 20-min protocol was reliable in trained cyclists.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.