Background
Volatile chemicals (VOCs) affect people's airways and maybe to be a risk factor to health if there is little culture of prevention, management and regulation in budding interior environments.
Objective
To identify factors that may increase the concentration of VOCs in the indoor environment of a university chemistry laboratory during student practice.
Method
The concentration was measured by portable flame ionisation detector in units of parts per million (ppm). It recorded three conditions: (a) with three extractors in to on and unlit, (b) practices study with volatile substances and unused, (c) instead of monitoring: front and back of the lab.
Results
The variability of VOCs ppm for each of the effects, statistically significant difference test, comparing their mean square against an estimate of experimental error. In this case, two effects have p<0.05, indicating that they are significantly different from zero with a confidence level of 95.0%. When exhaust fans are running, it is reported that 1578 ppm smaller than amount when not in operation (1804 ppm). The average concentration of VOCs is reported of 2.03 ppm without using volatile substances and increased to 28.27 ppm when used, locating this concentration at the bottom of the laboratory.
Conclusions Contribution
The concentration of VOCs increases when exhaust fans are not working and dispersed when operating only two of three extractors. With three fans, the VOCs were concentrated in a space and may be risk to health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.