The results of this study seems to confirm that ACL reconstruction in patients older than 50 years is a safe procedure with good to excellent subjective, objective, and radiological outcomes that are comparable to those for younger patients.
Background: Periprosthetic joint infection (PJI) represents 25% of failed total knee arthroplasties (TKA). The European Knee Associates (EKA) formed a transatlantic panel of experts to perform a literature review examining patient-related risk factors with the objective of producing perioperative recommendations in PJI high-risk patients. Methods: Multiple databases (Pubmed/MEDLINE, EMBASE, Scopus, Cochrane Library) and recommendations on TKA PJI prevention measures from the International Consensus Meetings on PJI from the AAOS and AAHKS were reviewed. This represents a Level IV study. Results: Strong evidence was found on poor glycemic control, obesity, malnutrition, and smoking being all associated with increased rates of PJI. In the preoperative period, patient optimization is key: BMI < 35, diet optimization, Hemoglobin A1c < 7.5, Fructosamine < 292 mmol/L, smoking cessation, and MRSA nasal screening all showed strong evidence on reducing PJI risk. Intraoperatively, a weight-based antibiotic prophylaxis, accurate fluid resuscitation, betadine and chlorhexidine dual skin preparation, diluted povidone iodine solution irrigation, tranexamic acid administration, and monofilament barbed triclosan-coated sutures for soft tissues closure all represented effective prevention measures. In the postoperative period, failure to reach normalization of ESR, CRP, D-dimer, and IL-6 six weeks postoperatively suggested early PJI. Conclusion: The current recommendations from this group of experts, based on published evidence, support risk stratification to identify high-risk patients requiring implementation of perioperative measures to reduce postoperative PJI.
Purpose: Treatment of patients with dementia and hip fracture is challenging. Total hip arthroplasty (THA) with dual mobility cup (DMC) has been designed to reduce the rate of dislocation by increasing the stability of the implant. This study aimed to compare the dislocation rates of DMC THA with hemiarthroplasty (HA) in elderly patients with displaced femoral neck fracture (FNF) and a diagnosis of dementia. Methods: All patients with a displaced FNF and dementia diagnosis were prospectively randomized to hemiarthroplasty or THA with DMC treatment during a 2-year period. Finally, the outcomes of 30 patients in the HA group were compared with those of 30 patients in the DMC THA group. Dislocation rate at a minimum follow-up of 1 year was evaluated as the primary outcome. Reoperation rate, time to surgery, surgical time, length of hospital stay, and 30-day and 1-year mortality were also evaluated. Results: There was a significant difference regarding rates of dislocation in favor of THA with DMC and with regard to length of surgery (p = 0.04) in favor of bipolar HA. Dislocation occurred in five patients (16.6%) treated with bipolar HA and no one (0%) in patients treated with THA with DMC (p = 0.019). There was no difference with regard to the 30-day mortality, 1-year mortality, reoperations, and length of hospital stay between the two groups of patients. Discussion: THA with DMC seems to be a safe and reliable choice to reduce the rate of dislocation at 1 year in patients with dementia and FNF without a higher risk of mortality.
Achieving a well-balanced total knee arthroplasty (TKA) is a difficult task, but the use of real-time sensing technology could provide intraoperative dynamic feedback regarding stability and load. This study compared intraoperative data and clinical outcomes between two cohorts, where one cohort had a sensor-guided medial pivot TKA performed. Methods: Two cohorts of 50 patients each were preoperatively matched to receive the same TKA, having a J-curve femoral design with an adapted “medially congruent” polyethylene insert; the second cohort (group B) underwent the intraoperative sensor-check. Intraoperative sensor data were recorded as tibiofemoral load at 10°, 45°, and 90°. We considered stable knees those with a pressure <50 lbs on the medial compartment, <35 lbs on the lateral, and a mediolateral inter-compartmental difference <15 lbs. Clinical outcomes were evaluated according to the Oxford Knee Score (OKS) and Knee Society Score (KSS). Results: All patients (group A: no sensor; group B: sensor) were available at 2-year minimum follow-up (FU; min. 24 months, max. 34 months); no preoperative statistical differences existed between groups in the average range of motion (ROM), OKS, KSS, and body mass index. There were no statistical differences at final FU between groups in the average OKS (group A: 41.1; group B: 41.5), in the average KSS (group A: 165.7; group B: 166.3), or in final ROM (group A: 123°; group B: 124°). One patient in each group required a manipulation under anesthesia. In the sensor group, an accessory soft tissue release/bone recut was necessary after sensor testing with trial components in 24% to obtain the desired loads; in the same group, the level of constraint in the final components was increased to posterior-stabilized in 12% because of an inter-compartmental difference >40 lbs. Surgical time was 8 min longer in the sensor group. Conclusion: The use of this sensing technology did not improve the clinical outcome but supported multiple intraoperative decisions aimed to better reproduce the medial pivot kinematic of the normal knee.
PurposeModern total knee arthroplasty (TKA) systems are designed to reproduce the normal knee kinematics and improve patient outcome. The authors compared two different third‐generation medial pivot TKA implants, having a single‐radius or a J‐curve design in their sagittal plane, hypothesizing no clinical differences. MethodsTwo cohorts of 50 patients who underwent primary TKA were first preoperatively matched by sex, deformity, body mass index (BMI), Oxford Knee Score (OKS), Knee society score (KSS) and range of motion (ROM) and then statistically analyzed at a minimum follow‐up (FU) of 2 years. An identical surgical technique, which aimed to reproduce a slightly tighter medial than lateral compartment, was used in all knees. ResultsAt a minimum follow‐up of 2 years (range 24–34 months) there were no statistically significant differences in OKS and KSS between the two implant groups. The final ROM differed statistically between the two groups: the average maximum active flexion was 123° in the J‐curve femoral design group with an adapted “medially‐congruent” polyethylene insert, and 116° in the single radius femoral design with a medial “ball‐in‐socket” articulation. ConclusionNo clinical and radiological differences were found when the two cohorts of patients were compared. This study showed that the implant design played a minor role in the final outcome as opposed to a precise surgical technique. Level of evidenceRetrospective case‐control study, Level III.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.