To verify the influence of axial length (AL) variations after cataract surgery in IOL power calculation. Patients underwent ophthalmic evaluation before surgery, including optical biometry with IOLMaster 500. Same exams were repeated 2 months after surgery: AL of operated eye was evaluated using two modes (pseudophakic/aphakic options). Mean Keratometry and AL changes were analyzed. Furthermore, refractive prediction error (PE) was back-calculated with Barrett Universal-II, Hoffer-Q, Holladay-1 and SRK/T formulas. To eliminate any systematic error, the mean error (ME) was zeroed-out for each formula. MEs and median absolute errors (MedAEs) of PEs were analyzed. Two-hundred-one operated eyes of 201 patients and 201 opposite eyes were evaluated. In operated eyes, mean AL difference was − 0.11 ± 0.07 mm (p < 0.001) with pseudophakic option and 0.00 ± 0.07 mm (p = 0.922) with aphakic option. There were not-statistically significant differences between MedAE of PEs calculated after zeroing-out the ME with different ALs (p > 0.05). Instead, only MEs of PEs obtained with postoperative ALs-pseudophakic option were not-statistically different from zero (p > 0.05). AL measurement change after cataract surgery is probably due to a systematic error in optical biometer in case of phakic eyes. A correction factor applied to preoperative AL could eliminate any systematic error in IOL power calculation without modifying the lens constant.
This observational study compared optic coherence tomography (OCT) and B-scan in the detection of optic disc drusen. In total, 86 eyes of 50 patients with optic disc drusen (ODD) (36 bilateral) with a mean age of 34.68 ± 23.81 years, and 54 eyes of 27 patients with papilledema, with a mean age of 35.42 years ± 17.47, were examined. Patients with ODD, diagnosed with ultrasound, underwent spectral-domain OCT evaluation. With US, 28 ODD cases were classified as large (4 buried and 24 superficial), 58 were classified as point-like (6 buried, 49 superficial and 3 mixed). Then, all patients underwent OCT. OCT was able to detect the presence of ODD and/or peripapillary hyperreflective ovoid mass structure (PHOMS) in 69 eyes (p < 0.001). In particular, 7 eyes (8.14%) showed the presence of ODD alone, 25 eyes (29.07%) showed only PHOMS and 37 eyes (43.02%) showed ODD and PHOMS. In 17 eyes (19.77%) no ODD or PHOMS were detected. In the papilledema group, no ODD were observed with both US and OCT. OCT showed the presence of drusen or similar lesions in only 80.23% of the cases highlighted by the US scan, so it does not allow for certain ODD diagnoses, especially in the case of buried ODD.
To test a new method to calculate the Intraocular Lens (IOL) power, that combines R Factor and ALxK methods, that we called Advance Lens Measurement Approach (ALMA).
This retrospective comparative study proposes a multi-formula approach by comparing no-history IOL power calculation methods after myopic laser-refractive-surgery (LRS). One-hundred-thirty-two eyes of 132 patients who had myopic-LRS and cataract surgery were examined. ALMA, Barrett True-K (TK), Ferrara, Jin, Kim, Latkany and Shammas methods were evaluated in order to back-calculate refractive prediction error (PE). To eliminate any systematic error, constant optimization through zeroing-out the mean error (ME) was performed for each formula. Median absolute error (MedAE) and percentage of eyes within ±0.50 and ±1.00 diopters (D) of PE were analyzed. PEs were plotted with corresponding mean keratometry (K), axial length (AL), and AL/K ratio; then, different ranges were evaluated. With optimized constants through zeroing-out ME (90 eyes), ALMA was better when K ≤ 38.00 D-AL > 28.00 mm and when 38.00 D < K ≤ 40.00 D-26.50 mm < AL ≤ 29.50 mm; Barrett-TK was better when K ≤ 38.00 D-AL ≤ 26.50 mm and when K > 40.00 D-AL ≤ 28.00 mm or AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges. (p < 0.05) Without modified constants (132 eyes), ALMA was better when K > 38.00 D-AL ≤ 29.50 mm and when 36.00 < K ≤ 38.00 D-AL ≤ 26.50 mm; Barrett-TK was better when K ≤ 36.00 D and when K ≤ 38.00 D with AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges (p < 0.05). A multi-formula approach, according to different ranges of K and AL, could improve refractive outcomes in post-myopic-LRS eyes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.