A general scheme is presented for controlling quantum systems using evolution driven by nonselective von Neumann measurements, with or without an additional tailored electromagnetic field.As an example, a 2-level quantum system controlled by non-selective quantum measurements is considered. The control goal is to find optimal system observables such that consecutive nonselective measurement of these observables transforms the system from a given initial state into a state which maximizes the expected value of a target operator (the objective). A complete analytical solution is found including explicit expressions for the optimal measured observables and for the maximal objective value given any target operator, any initial system density matrix, and any number of measurements. As an illustration, upper bounds on measurement-induced population transfer between the ground and the excited states for any number of measurements are found. The anti-Zeno effect is recovered in the limit of an infinite number of measurements. In this limit the system becomes completely controllable. The results establish the degree of control attainable by a finite number of measurements.
This paper explores the utility of instantaneous and continuous observations in the optimal control of quantum dynamics. Simulations of the processes are performed on several multilevel quantum systems with the goal of population transfer. Optimal control fields are shown to be capable of cooperating or fighting with observations to achieve a good yield, and the nature of the observations may be optimized to more effectively control the quantum dynamics. Quantum observations also can break dynamical symmetries to increase the controllability of a quantum system. The quantum Zeno and anti-Zeno effects induced by observations are the key operating principles in these processes. The results indicate that quantum observations can be effective tools in the control of quantum dynamics.
The aim of the study was to evaluate the efficacy custom 3D-printed osteosynthesis plates in the treatment of intercondylar humeral fractures.Thirteen patients with distal intercondylar humeral fractures were randomized to undergo surgery using either conventional plates (n = 7) or 3D-printed plates (n = 6) at our institution from March to October 2014. Both groups were compared in terms of operative time and elbow function at 6 month follow-up.All patients were followed-up for a mean of 10.6 months (range: 6–13 months). The 3D-printing group had a significantly shorter mean operative time (70.6 ± 12.1 min) than the conventional plates group (92.3 ± 17.4 min). At the last follow-up period, there was no significant difference between groups in the rate of patients with good or excellent elbow function, although the 3D-printing group saw a slightly higher rate of good or excellent evaluations (83.1%) compared to the conventional group (71.4%).Custom 3D printed osteosynthesis plates are safe and effective for the treatment of intercondylar humeral fractures and significantly reduce operative time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.