This study analyzes the performance of wooden structural floors equipped with the self-tensioning system patented by the authors, consisting of a force multiplying mechanism connected to a self-tensioning tendon, which is activated automatically when the load is applied to the structural element. The paper describes the system’s difficulties when the structural floor is subjected to asymmetrical loads. The proposed solution consists of anchoring the tendon by an adhesive connection in the central part of the piece yielding a favorable redistribution of the bending moments and an effective performance in terms of deformations. The comparative study focuses onπ-shape cross section pieces with spans of 12 m and 15 m, using sections without prestressing and with initial prestressing and self-tensioning system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.