Carbamylation of LDL induces endothelial dysfunction via LOX-1 activation and increased ROS production leading to eNOS uncoupling. This indicates a novel mechanism in the pathogenesis of atherosclerotic disease which may be pathogenic and prognostic in patients with CKD and high plasma levels of cLDL.
Background For peripheral artery disease (PAD), MR angiography (MRA) is a well‐established diagnostic modality providing morphologic and dynamic information comparable to digital subtraction angiography (DSA). However, relatively large amounts of contrast agents are necessary to achieve this. Purpose To evaluate the diagnostic accuracy of time‐resolved 4D MR‐angiography with interleaved stochastic trajectories (TWIST‐MRA) by using maximum intensity projections (MIPs) of dynamic images acquired with reduced doses of contrast agent. Study Type Retrospective. Population Forty adult PAD patients yielding 1088 artery segments. Field Strength/Sequence A 3.0 T, time‐resolved 4D MR‐angiography with TWIST‐MRA and MIP of dynamic images. Assessment DSA was available in 14 patients (256 artery segments) and used as reference standard. Three‐segmental MIP reconstructions of TWIST‐images after administration of 3 mL of gadolinium‐based contrast agent (Gadoteridol/Prohance®, 0.5 M) per anatomical level (pelvis, thighs, and lower legs) yielded 256 artery segments for correlation between MRA and DSA. Three independent observers rated image quality (scale: 1 [nondiagnostic] to 4 [excellent]) and the degree of venous overlay (scale: 0 [none] to 2 [significant]) for all segments. Diagnostic accuracy for the detection of >50% stenosis and artery occlusion was calculated for all observers. Statistical Tests Binary classification test (sensitivity, specificity, positive/negative predictive values, diagnostic accuracy). Intraclass correlation coefficients (ICCs), logistic regression analysis with comparison of areas under the receiver‐operating‐characteristics (ROC) curves (AUCs) with the DeLong method. Bland–Altman‐comparison. Results High diagnostic performance was achieved for the detection of >50% stenosis (sensitivity 92.9% [84.3–99.9% (95%‐CI)] and specificity 98.5% [95.7–99.8% (95%‐CI)]) and artery occlusion (sensitivity 93.1% [77.2–99.2% (95%‐CI)] and specificity 99.1% [96.9–99.9% (95%‐CI)]). Inter‐reader agreement was excellent with ICC values ranging from 0.95 to 1.0 for >50% artery stenosis and occlusion. Image quality was good to excellent for both readers (3.41 ± 0.72, 3.33 ± 0.65, and 3.38 ± 0.61 [mean ± SD]) with good correlation between observer ratings (ICC 0.71–0.81). No significant venous overlay was observed (0.06 ± 0.24, 0.23 ± 0.43 and 0.11 ± 0.45 [mean ± SD]). Data Conclusion MIPs of dynamic TWIST‐MRA offer a promising diagnostic alternative necessitating only reduced amounts (50%) of gadolinium‐based contrast agents for the entire runoff vasculature. Evidence Level 3 Technical Efficacy Stage 2
Background Internal herniation of small intestine in the lesser pelvis alongside iliac vasculature is a rare occurrence. Skeletonization of iliac vessels during pelvic lymph node dissection (LND), as part of surgical staging or treatment of patients with uterine, ovarian or urogenital cancer, is a strict prerequisite for orifice formation. Case presentation A 68-year-old woman presented at the emergency department with complaints of constipation for the last 3 days and acute-onset abdominal pain, nausea and vomiting since few hours. She had a history of laparoscopic hysterectomy, bilateral salpingo-oophorectomy and para-aortic and pelvic LND 7 years ago. A distended abdomen with diffuse tenderness on palpation was noted. A CT scan demonstrated bowel obstruction secondary to an incarcerated hernia underneath an elongated right external iliac artery. During an emergency exploratory laparotomy, the incarcerated bowel was reduced and the hernial orifice closed with a running suture. The patient had an uneventful postoperative period and was discharged on the fifth postoperative day. Discussion This rare internal hernia can manifest with non-specific symptoms of small bowel obstruction at any given point after index surgery, sometimes even after several years free of complaints. Contrast-enhanced computed tomography is the method of choice for fast and reliable diagnosis and helps in planning the necessary emergency laparotomy. Conclusion This life-threatening complication adds to the current controversy of pelvic and para-aortic lymphadenectomy in patients with endometrial cancer. Primary closure of peritoneal defects should be considered to potentially prevent internal hernias, especially when elongated iliac vessels are present.
Objectives: The aim of this study was to compare the diagnostic accuracy of apparent diffusion coefficient (ADC) ratios as a monoparametric magnetic resonance imaging (MRI) protocol for the detection of prostate cancer (PCa) with the established multiparametric (mp) MRI at 3.0 T. Materials and Methods: According to power analysis, 52 male patients were included in this monocenter study with prospective data collection and retrospective, blinded multireader image analysis. The study was approved by the local ethics committee. Patients were recruited from January to December 2020. Based on mpMRI findings, patients underwent in-bore MR biopsy or prostatectomy for histopathologic correlation of suspicious lesions. Three readers, blinded to the histopathologic results and images of mpMRI, independently evaluated ADC maps for the detection of PCa. The ADC ratio was defined as the lowest signal intensity (SI) of lesions divided by the SI of normal tissue in the zone of origin. Predictive accuracy of multiparametric and monoparametric MRI were compared using logistic regression analysis. Moreover, both protocols were compared applying goodness-of-fit analysis with the Hosmer-Lemeshow test for continuous ADC ratios and Pearson χ 2 test for binary decision calls, correlation analysis with Spearman ρ and intraclass correlation coefficients, as well as noninferiority assessment with a TOST ("two one-sided test").Results: Eighty-one histopathologically proven, unique PCa lesions (Gleason score [GS] ≥ 3 + 3) in 52 patients could be unequivocally correlated, with 57 clinically significant (cs) PCa lesions (GS ≥ 3 + 4). Multiparametric MRI detected 95%, and monoparametric ADC detected ratios 91% to 93% of csPCa. Noninferiority of monoparametric MRI was confirmed by TOST ( P < 0.05 for all comparisons). Logistic regression analysis revealed comparable predictive diagnostic accuracy of ADC ratios (73.7%-87.8%) versus mpMRI (72.2%-84.7%). Spearman rank correlation coefficient for PCa aggressiveness revealed satisfactory correlation of ADC ratios ( P < 0.013 for all correlations). The Hosmer-Lemeshow test for the logistic regression analysis for continuous ADC ratios indicated adequate predictive accuracy ( P = 0.55-0.87), and the Pearson χ 2 test showed satisfactory goodness of fit ( P = 0.35-0.69, χ 2 = 0.16-0.87). Conclusions: Normalized ADC ratios based on advanced DWI are noninferior to mpMRI at 3.0 T for the detection of csPCa in a preselected patient cohort and proved a fast and accurate assessment tool, thus showing a potential prospect of easing the development of future screening methods for PCa.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.