The objective of the present study is to evaluate how the elastic properties of the fabrication material of dental implants influence peri-implant bone load transfer in terms of the magnitude and distribution of stress and deformation. A three-dimensional (3D) finite element analysis was performed; the model used was a section of mandibular bone with a single implant containing a cemented ceramic-metal crown on a titanium abutment. The following three alloys were compared: rigid (Y-TZP), conventional (Ti-6Al-4V), and hyperelastic (Ti-Nb-Zr). A 150-N static load was tested on the central fossa at 6° relative to the axial axis of the implant. The results showed no differences in the distribution of stress and deformation of the bone for any of the three types of alloys studied, mainly being concentrated at the peri-implant cortical layer. However, there were differences found in the magnitude of the stress transferred to the supporting bone, with the most rigid alloy (Y-TZP) transferring the least stress and deformation to cortical bone. We conclude that there is an effect of the fabrication material of dental implants on the magnitude of the stress and deformation transferred to peri-implant bone.
Objectives: The aim of this prospective clinical trial was to evaluate the success implant rates during 24 months using OSFE procedure without grafting materials. Study design: 42 adult patients (22 female, 15 male) were selected according to Nedir et al´s inclusion criteria of which 5 patients were excluded, due to periapical pathology in adjacent teeth (n=3) and treatment with bisphosphonates (n=2). 37 patients aged 31-68 years were selected. Smokers were divided in two groups depending on the number of cigarettes consumed per day (a) 0-10, (b) 11-20. One patient was excluded because he was lost to follow-up at 24 months A total of 36 threaded implants were placed, ∅4,1mm Straumann® (Straumann AG, Waldenburg, Switzerland) and ∅3,5mm Klockner® (Klockner Implant System, Barcelona, Spain). The most used implant diameter was 4,1 mm (n=29), followed by 3,5 mm (n=7), and length used was 10 mm (n=32) and 8 mm (n=4). Initial RBH ranged from 4 mm to 9 mm. All statistical data were processed using the program R 3.0.2 for windows. Results: A total of 36 threaded implants were placed. Residual bone height (RBH) at implant placement averaged 7,4 ± 0,4 mm. Mean bone gain was 1,8 ± 0,3 mm. Four implants showed a bone gain exceeding 3 mm. Mean implant protrusion length into the sinus amounted to 2.1 ± 0,3 mm. Regarding the relationship between smoking and periodontal probes, no statistically significant differences were found (P=0,25), neither in relation to the number of threads that the implants showed (P=0,29) or bone gain (P=0,79). After 24 months the implant success rate was 91,6%. Conclusions: Implant rehabilitation of edentulous atrophied posterior maxilla can be safely performed and simplified using the OSFE technique without grafting with reliable long-term results. Key words:Crestal bone loss, dental implants, internal sinus lift, no grafting, osteotome sinus elevation, grafting, sinus floor elevation.
Objectives The aim of this literature systematic review was to evaluate the possible association between malocclusions, orthodontic treatment and development of temporomandibular disorders. Material and Methods: A search was carried out on PubMed-Medline database from January 2000 to August 2013 using the keywords “orthodontics and temporomandibular disorders”, “orthodontics and facial pain” and “malocclusion and temporomandibular disorders”. Human studies included in the study were those assessing signs and symptoms of temporomandibular disorders in relation to orthodontic treatment. Material and Methods A search was carried out on PubMed-Medline database from January 2000 to August 2013 using the keywords “orthodontics and temporomandibular disorders”, “orthodontics and facial pain” and “malocclusion and temporomandibular disorders”. Human studies included in the study were those assessing signs and symptoms of temporomandibular disorders in relation to orthodontic treatment. Results The search strategy resulted in 61 articles. After selection according to the inclusion/exclusion criteria 9 articles qualified for the final analysis. The articles which linked orthodontics and development of temporomandibular disorders showed very discrepant results. Some indicated that orthodontic treatment could improve signs and symptoms of temporomandibular disorders, but none of them obtained statistically significant differences. Conclusions According to the authors examined, there is no evidence for a cause-effect relationship between orthodontic treatment and temporomandibular disorders, or that such treatment might improve or prevent them. More longitudinal studies are needed to verify any possible interrelationship. Key words:Malocclusion and temporomandibular disorders, orthodontics and facial pain, orthodontics and temporomandibular disorders, temporomandibular disorders, temporomandibular dysfunction.
BackgroundThis study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA).Material and MethodsThirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remaining 16 sites were prepared using an oversize drilling technique (overpreparation) to a working depth of 12mm. Bone density was determined using cone beam computerized tomography (CBCT). The implants were placed and primary stability was measured by two methods: insertion torque (Ncm), and RFA (implant stability quotient [ISQ]).ResultsThe highest torque values were achieved by the conventional drilling technique (10mm). The ANOVA test confirmed that there was a significant correlation between torque and drilling depth (p<0.05). However, no statistically significant differences were obtained between ISQ values at 10 or 12 mm drilling depths (p>0.05) at either measurement direction (cortical and medullar). No statistical relation between torque and ISQ values was identified, or between bone density and primary stability (p >0.05).ConclusionsVertical overpreparation of the implant bed will obtain lower insertion torque values, but does not produce statistically significant differences in ISQ values. Key words:Implant stability quotient, overdrilling, primary stability, resonance frequency analysis, torque.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.