Obstructive sleep apnea syndrome (OSAS) is a common disorder characterized by repeated episodes of upper airways collapse during the sleep. The following intermittent hypoxia triggers a state of chronic inflammation, which also interests the nervous system leading to neuronal damage and increased risk of cognitive impairment. Brain derived neurotrophic factor (BDNF) is a growth factor often associated with neuroplasticity and neuroprotection whose levels increase in several condition associated with neuronal damage. However, whether patients affected by OSAS have altered BDNF levels and whether such alteration may be reflective of their cognitive impairment is still controversial. Here we show that, when compared to healthy control volunteers, OSAS patients have increased serum levels of BDNF. Moreover, OSAS patients with the higher levels of BDNF also have reduced neurocognitive impairment as measured by The Montreal Cognitive Assessment (MoCA) questionnaire. Treatment with standard non-invasive mechanical ventilation (CPAP) also was able to ameliorate the level of cognitive impairment. Altogether our results indicate that BDNF levels represent a neuroprotective response to intermittent hypoxia in OSAS patients.
Lung hyperinflation is a feature of chronic obstructive pulmonary disease (COPD) and can determine pivotal consequence on symptoms, exercise tolerance and quality of life. Despite the relevance of assessing lung hyperinflation, there is still no single consensus as to what volume should be taken into account. We investigate which spirometric measurement is more reliable in assessing static lung hyperinflation and which is more related with impulse oscillometry system (IOS) measurements in COPD. Patients and Methods: Fifty-five COPD patients were enrolled. TLC, RV and RV:TLC ratio were obtained both with helium and plethysmography techniques. IOS measurements (X5, Fres and R5-R20) were performed. Pearson and Spearman correlation determined the relationships between the functional parameters that evaluate static hyperinflation (RV: TLC, TLC, RV) and IOS measurements. Results: As expected, we reported a statistically significant difference between these two techniques in terms of mean percentage values of TLC (7.57 ± 3.26 L; p= 0.02) and RV (15.24 ± 7.51 L; p=0.04), while RV:TLC measured with the two methods was similar (5.21 ± 4.69%; p=0.27). The correlation analysis showed that IOS parameters, such as difference in resistance between 5 Hz and 20 Hz (R(5-20)) and resonant frequency (Fres), were positively correlated with RV:TLC ratio, while reactance at 5 Hz (X(5)) was negatively correlated with it. In particular, we pointed out a weak correlation between RV:TLC (%) (Pleth) and R(5-20) (r=0.3, p=0.04), Fres (r=0.3; p=0.03), while X5 had a mild correlation with RV:TLC (%) (r= −0.5;p<0.0001). Moreover, we noticed a strong relationship between RV:TLC (%)(He) and X5 (r=−0.7; p=0.0001) and a mild correlation between RV:TLC (%) (He) and Fres (r=0.4; p=0.003). Between R5-R20 and RV:TLC, there was a weak correlation (r=0.3; p=0.001). No correlation between TLC, RV (L,%) (both helium and Pleth derived) and IOS parameters (R (5-20), X5, Fres) was found. Conclusion: RV:TLC can represent the most reliable parameter in the assessment of hyperinflation, considering the absence of significant difference in its measurement between the two techniques. IOS provides supplementary information in the assessment of static hyperinflation.
Percutaneous TAVR induces an angiographically detectable CFA lumen reduction. Such findings call for further studies assessing clinical impact of this phenomenon and open the door for further refinements of the TAVR access management aimed at preserving vessel integrity.
Background: The diagnosis of COPD is based on both clinical signs and functional tests. Although there are different functional tests used to assess COPD, no reliable biomarkers able to provide information on pathogenesis and severity are available. The aim of the present study is to explore the relationship between surfactant protein B (Sp-B) serum levels and clinical, radiological, and functional pulmonary parameters in COPD patients. Methods: Forty COPD patients and twenty smokers without airflow limitations or respiratory symptoms were enrolled. Each patient was given questionnaires (CAT and mMRC) and 6MWT, spirometry, DLCO, and computer tomography (CT) were performed. All participants underwent a venous blood sample drawing, and quantitative detection of their Sp-B plasma levels was performed by an enzyme-linked immunosorbent assay. The spirometry and Sp-B plasma levels were assessed after 12 months. Results: A statistically significant difference was found in the plasma Sp-B levels between COPD patients compared to the other group (4.72 + 3.2 ng/mL vs. 1.78 + 1.5 ng/mL; p < 0.001). The change in FEV1 after 12 months (Delta FEV1) showed a significantly negative correlation with respect to the change in Sp-B levels (Delta SpB) (r = −0.4; p < 0.05). This correlation indicates that increasing the plasma dosage of SpB is a foretoken of functional decline. Conclusions: SpB may be considered as a useful marker in COPD assessment and provides prognostic information on lung functional decline. Despite its usefulness, further studies are needed to define its reliability as a biomarker.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.