A novel, simple to apply, and economic buckling restrainer system is introduced for steel plate shear walls. The shear wall panel is restrained by parallel non-welded channel restrainers, which are installed on both sides of the steel panel. A set of experiments were designed to examine improvement in the seismic performance of the shear wall due to the application of the proposed restrainer system. Three 1/4-scale down single-story single-bay steel panel specimens including one panel without and two panels with different number of restainers are subjected to cyclic loading. The behavior of steel panel with and without the restrainers is assessed in terms of initial stiffness, ultimate loading capacity, stiffness/strength degradation, and energy dissipation capacity. The use of the proposed restrainer system significantly improves the energy dissipation capacity of the shear wall and this enhancement is increasing at larger drifts. Employing the proposed restrainer system, there is only a slight increase in the ultimate loading capacity, and at the same time, a significant increase in the initial stiffness of the shear wall. No strength degradation is observed for the range of the drifts up to 5%. A design recommendation for the sizing of the parallel restrainer components is also included.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.