Anemia remains an important global health problem. Inexpensive, accurate, and noninvasive solutions are needed to monitor and evaluate anemia in resource-limited settings. We evaluated the performance of multiple point-of-care hemoglobin devices, including a novel noninvasive smartphone application tested on Apple® and Android® cell phones, Masimo Pronto®, and HemoCue® Hb-301 and Hb-801, against a gold-standard hematology analyzer (reference hemoglobin) using venous blood. We examined correlations between hemoglobin devices and reference hemoglobin, device accuracy (average bias, Bland-Altman plots, clinical performance) and classification bias (sensitivity, specificity) among 299 refugees (10mo-65y) in Atlanta, GA. Semi-structured interviews (n = 19) with participants and staff assessed usability and acceptability. Mean reference hemoglobin was 13.7 g/dL (SD:1.8) with 12.5% anemia. Noninvasive hemoglobin devices were not well correlated with reference hemoglobin (Apple® R2 = 0.08, Android® R2 = 0.11, Masimo Pronto® R2 = 0.29), but stronger correlations were reported with HemoCue® Hb-301 (R2 = 0.87) and Hb-801 (R2 = 0.88). Bias (SD) varied across each device: Apple®: -1.6 g/dL (2.0), Android®: -0.7 g/dL (2.0), Masimo Pronto®: -0.4 g/dL (1.6), HemoCue® Hb-301: +0.4 g/dL (0.7) and HemoCue® Hb-801: +0.2 g/dL (0.6). Clinically acceptable performance (within ± 1 g/dL of reference hemoglobin) was higher for the invasive devices (HemoCue® Hb-301: 90.3%; HemoCue® Hb-801: 93.4%) compared to noninvasive devices (Apple®: 31.5%; Android®: 34.6%; Masimo Pronto®: 49.5%). Sensitivity and specificity were 63.9% and 48.2% for Apple®, 36.1% and 67.6% for Android®, 45.7% and 85.3% for Masimo Pronto®, 54.3% and 97.6% for HemoCue® Hb-301, and 66.7% and 97.6% for HemoCue® Hb-801. Noninvasive devices were considered easy to use and were the preferred method by participants. Among the only studies to compare multiple point-of-care approaches to hemoglobin testing, the diagnostic ability of HemoCue® was comparable to reference hemoglobin, while noninvasive devices had high user acceptability but considerable biases. Improvements in noninvasive device performance and further testing in anemic populations are recommended before broader use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.