CCQM-K120.a comparison involves preparing standards of carbon dioxide in air which are fit for purpose for the atmospheric monitoring community, with stringent requirements on matrix composition and measurement uncertainty of the CO2 mole fraction. This represents an analytical challenge and is therefore considered as a Track C comparison. The comparison will underpin CMC claims for CO2 in air for standards and calibrations services for the atmospheric monitoring community, matrix matched to real air, over the mole fraction range of 250 μmol/mol to 520 μmol/mol. CCQM-K120.b comparison tests core skills and competencies required in gravimetric preparation, analytical certification and purity analysis. It is considered as a Track A comparison. It will underpin CO2 in air and nitrogen claims in a mole fraction range starting at the smallest participant's reported expanded uncertainty and ending at 500 mmol/mol. Participants successful in this comparison may use their result in the flexible scheme and underpin claims for all core mixtures This study has involved a comparison at the BIPM of a suite of 44 gas standards prepared by each of the participating laboratories. Fourteen laboratories took part in both comparisons (CCQM-K120.a, CCQM-K120.b) and just one solely in the CCQM-K120.b comparison. The standards were sent to the BIPM where the comparison measurements were performed. Two measurement methods were used to compare the standards, to ensure no measurement method dependant bias: GC-FID and FTIR spectroscopic analysis corrected for isotopic variation in the CO2 gases, measured at the BIPM using absorption laser spectroscopy. Following the advice of the CCQM Gas Analysis Working Group, results from the FTIR method were used to calculate the key comparison reference values. KEY WORDS FOR SEARCH FTIR, CO2, GC-FID, Carbon dioxide at background level, Carbon dioxide at urban level, Delta Ray, CO2 gas standards Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Rhoderick, GC, et al. 2019. Stability of gaseous volatile organic compounds contained in gas cylinders with different internal wall treatments. Elem Sci Anth, 7: 28.Measurements of volatile organic compounds (VOCs) have been ongoing for decades to track growth rates and assist in curbing emissions of these compounds into the atmosphere. To accurately establish mole fraction trends and assess the role of these gas-phase compounds in atmospheric chemistry it is essential to have good calibration standards. A necessity and precursor to accurate VOC gas standards are the gas cylinders and the internal wall treatments that aid in maintaining the stability of the mixtures over long periods of time, measured in years. This paper will discuss the stability of VOC gas mixtures in different types of gas cylinders and internal wall treatments. Stability data will be given for 85 VOCs studied in gas mixtures by National Metrology Institutes and other agency laboratories. This evaluation of cylinder treatment materials is the outcome of an activity of the VOC Expert Group within the framework of the World Meteorological Organization (WMO) Global Atmospheric Watch (GAW) program.
There is a high international priority attached to activities which reduce NOx in the atmosphere. The current level of permitted emissions is typically between 50 µmol/mol and 100 µmol/mol, but lower values are expected in the future. Currently, ambient air quality monitoring regulations also require the measurement of NOx mole fractions as low as 0.2 µmol/mol. The production of accurate standards at these levels of mole fractions requires either dilution of a stable higher concentration gas standard or production by a dynamic technique, for example one based on permeation tubes.The CCQM-K74 key comparison was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities and standards for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol.The measurements of this key comparison took place from June 2009 to May 2010.Seventeen laboratories took part in this comparison coordinated by the BIPM and VSL. The key comparison reference value was based on BIPM measurement results, and the standard measurement uncertainty of the reference value was 0.042 µmol/mol.This key comparison demonstrated that the results of the majority of the participants agreed within limits of ±3% relative to the reference value. The results of only one laboratory lay significantly outside these limits. Likewise this comparison made clear that a full interpretation of the results of the comparison needed to take into account the presence of nitric acid (in the range 100 nmol/mol to 350 nmol/mol) in the cylinders circulated as part of the comparison, as well as the possible presence of nitric acid in the primary standards used by participating laboratories.Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
The development and operation of a highly accurate primary gas facility for the dynamic production of mixtures of nitrogen dioxide (NO(2)) in nitrogen (N(2)) based on continuous weighing of a permeation tube and accurate impurity quantification and correction of the gas mixtures using Fourier transform infrared spectroscopy (FT-IR) is described. NO(2) gas mixtures in the range of 5 μmol mol(-1) to 15 μmol mol(-1) with a standard relative uncertainty of 0.4% can be produced with this facility. To achieve an uncertainty at this level, significant efforts were made to reduce, identify and quantify potential impurities present in the gas mixtures, such as nitric acid (HNO(3)). A complete uncertainty budget, based on the analysis of the performance of the facility, including the use of a FT-IR spectrometer and a nondispersive UV analyzer as analytical techniques, is presented in this work. The mixtures produced by this facility were validated and then selected to provide reference values for an international comparison of the Consultative Committee for Amount of Substance (CCQM), number CCQM-K74, (1) which was designed to evaluate the consistency of primary NO(2) gas standards from 17 National Metrology Institutes.
The CCQM-K90 comparison is designed to evaluate the level of comparability of National Metrology Institutes (NMI) or Designated Institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 µmol mol-1 .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.