Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a 100 microm:200 microm sudden expansion. Micro-flow visualization revealed a strong influence of hematocrit upon the path of RBCs and spatial concentration of particles. At all flow rates studied (Re = 8.3-41.7) and hematocrit 20% and lower, RBC streamlines were found to detach from the microchannel wall creating an RBC-depleted zone inside the step that was much larger than the cells themselves. However, the observed distribution of particles was relatively homogeneous. By contrast, the RBC streamlines of samples with hematocrit equal to or greater than 30% more closely followed the contour of the microchannel, yet exhibited enhanced concentration of particles within the corner. The corresponding size of the cell depletion layer was comparable with the size of the cells. This study implies that local platelet concentration in blood within the physiological range of hematocrit can be elevated within the flow separation region of a sudden expansion and implicates the role of RBCs in causing this effect.
Day-to-day observations reveal numerous medical and social situations where maintaining physical distancing is either not feasible or not practiced during the time of a viral pandemic, such as, the coronavirus disease 2019 (COVID-19). During these close-up, face-to-face interactions, a common belief is that a susceptible person wearing a face mask is safe, at least to a large extent, from foreign airborne sneeze and cough droplets. This study, for the first time, quantitatively verifies this notion. Droplet flow visualization experiments of a simulated face-to-face interaction with a mask in place were conducted using the particle image velocimetry setup. Five masks were tested in a snug-fit configuration (i.e., with no leakage around the edges): N-95, surgical, cloth PM 2.5, cloth, and wetted cloth PM 2.5. Except for the N-95 mask, the findings showed leakage of airborne droplets through all the face masks in both the configurations of (1) a susceptible person wearing a mask for protection and (2) a virus carrier wearing a mask to prevent the spreading of the virus. When the leakage percentages of these airborne droplets were expressed in terms of the number of virus particles, it was found that masks would not offer complete protection to a susceptible person from a viral infection in close (e.g., <6 ft) face-to-face or frontal human interactions. Therefore, consideration must be given to minimize or avoid such interactions, if possible. This study lends quantitative support to the social distancing and mask-wearing guidelines proposed by the medical research community.
The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.