Background: Several modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between cemented polyethylene glenoid (PEG) and three examples of modern MBG designs. Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into three groups based on follow-up duration: < 36month, 36-72-month, and > 72-month subgroups.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21-93) and 66.5 years (31-88). The mean duration of follow-up was 73.1 (12-211) and 56.1 months (24-100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15%) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of < 36-month and 36-72-month subgroups showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P = 0.754 and 0.829, respectively). In the > 72-month subgroup, MBG was better in terms of loosening (P < 0.001) and failure rates (P = 0.006). Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. Three modern MBG designs seem to have no difference in failure, at least in the < 36-month and 36-72-month subgroups compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted. Level of evidence: Level IV, systematic review.
Background: Despite the increased popularity of reverse total shoulder arthroplasty, total shoulder arthroplasty is the standard treatment for advanced shoulder arthritis in young adult patients. Conventional metal-backed glenoid (MBG) designs result in more loosening and revision surgery compared with cemented polyethylene glenoid components. However, modern MBG designs have been recently devised to overcome such drawbacks. Purpose: To compare the radiolucency, loosening, and failure rates of modern MBG designs with those of conventional designs. Study Design: Systematic review; Level of evidence, 4. Methods: A search for relevant articles was carried out using the PubMed, Cochrane Library, and Embase databases using MeSH (Medical Subject Headings) terms and natural keywords. A total of 362 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed categorical data, such as the presence of loosening, failure, and revision surgery. The main outcome was the rate of revision surgery or failure. Subgroup analysis according to follow-up duration was performed to reduce heterogeneity. Results: A total of 25 articles (2036 shoulders) were included; 15 articles (1579 shoulders) involved a conventional MBG design, and 10 (457 shoulders) involved a modern design. The mean age of the patients was 64.2 and 66.5 years in the conventional and modern design groups, respectively, with a mean follow-up duration of 102.0 and 56.1 months, a mean gain of forward elevation of 35.1° and 61.7°, and a mean gain of external rotation of 24.2° and 39.2°. The rate of radiolucency was 48.0% and 16.7%, the rate of loosening was 11.2% and 4.9%, and the rate of revision was 15.9% and 2.4%, for the conventional and modern design groups, respectively. Subgroup analysis according to follow-up duration showed that the rates of loosening and revision were significantly lower in the modern design group ( P < .001). Conclusion: Our findings suggest that modern MBG designs showed significantly lower loosening and failure rates than conventional designs. The overall results of the comparison, including loosening, failure, change in range of motion, and clinical scores, indicate that modern MBG designs are promising. More long-term follow-up studies on modern MBGs should be conducted.
BACKGROUND: Data are lacking on trends in bariatric surgery and the frequency of incidental findings in Saudi Arabia. OBJECTIVE: Report on trends in bariatric surgery as well as our experience in incidental findings along with a literature review (mainly on gastrointestinal stromal tumor). DESIGN: Retrospective chart and literature review. SETTINGS: Academic tertiary care center. PATIENTS AND METHODS: We conducted a retrospective study at King Khalid University Hospital and analyzed the data collected from 2009 to 2019. We collected data on age, body mass index (BMI), H pylori infection, type of bariatric surgery performed, and type and location of incidental findings. MAIN OUTCOME MEASURES: Incidental findings during or after bariatric surgery (in pathology specimen). SAMPLE SIZE: 3052 bariatric surgeries, 46 patients with incidentalomas. RESULTS: The mean and standard deviation for the age of the 46 patients with incidentalomas was 42.1 (13.9) years and the mean (SD) preoperative BMI was 43.4 (6.4) kg/m 2 . Of 3052 bariatric surgeries performed, the most common type was sleeve gastrectomy (93.9%), followed by gastric bypass surgery (4.58%) and gastric banding (1.47%). The total frequency of incidentalomas was 1.5%; 10.8% of patients had gastrointestinal stromal tumors (GIST), with the stomach being the commonest site for incidental findings. Eighty percent of the patients with GIST were positive for H pylori ( P =.01 vs negative patients). CONCLUSION: The number of incidentalomas and other findings were consistent with other reports. All these findings suggest that bariatric surgeons should take special care before, during, and after a laparoscopic operation in obese patients. LIMITATIONS: Since this is a single-center, retrospective study, we did not collect data on important variables such as gender, socioeconomic status of the patient, and family history of obesity, and we did not perform a preoperative esophagogastroduodenoscopy. CONFLICT OF INTEREST: None.
Introduction An optimal hip implant is biocompatible, durable, and resistant to chemical and mechanical wear. This analysis aimed to compare failure (revision) and complication rates between ceramic-on-ceramic (CoC) and ceramic-on-highly-crosslinked-polyethylene (CoHXLPE) implants. Methods This review comprised of scientific literature published between 1995 and 2019. We included randomized controlled trials in adults (>18 years) that presented results of CoC and CoHXLPE total hip arthroplasty (THA) with more than two years of mean follow-up and drafted in English. The primary outcomes for this analysis were complications, revision rates, and loosening rates. Results Eight studies (1,689 hips) were included in this systematic review. There was no significant differences between COC and CoHXLPE for the risk of post-surgical complications (relative risk [RR]: 1.98, 95% confidence interval [CI]: 0.83-4.69, P = 0.12). Revision rates (RR: 1.25, 95% CI: 0.71-2.20, P = 0.43] and loosening rates between the two implants were not significantly different (RR: 1.17, 95% CI: 0.30-4.52, P = 0.82). Conclusion We report no significant differences between CoHXLPE and CoC in adults undergoing primary THA. Although introduced relatively recently, CoHXLPE is a cost-effective bearing that can be used for younger patients with no risk of increased complications in comparison to CoC. Further studies with longer follow-up periods are recommended to confirm the findings of this meta-analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.