In this contemporary study, overall serious adverse events after AM were lower than previously reported. However, patients with left ventricular ejection fraction <50%, ventricular arrhythmias, or low cardiac output syndrome at presentation were at higher risk compared with uncomplicated cases that had a benign prognosis and low risk of subsequent left ventricular systolic dysfunction.
An intrathoracic impedance-derived fluid index had low sensitivity and PPV in the early period after implantation of a device in chronic HF patients. Sensitivity improved within the first 6 months after implant. Further studies are needed to assess the place of this monitoring technology in the clinical management of patients with HF.
AimsRegistries and surveys improve knowledge of the 'real world'. This paper aims to describe baseline clinical profiles, management strategies, and the in-hospital outcome of patients admitted to hospital for an acute heart failure (AHF) episode.
Methods and results
IN-HFOutcome is a nationwide, prospective, multicentre, observational study conducted in 61 Cardiology Centres in Italy. Up to December 2009, 5610 patients had been enrolled, 1855 (33%) with AHF and 3755 (67%) with chronic heart failure (CHF). Baseline and in-hospital outcome data of AHF patients are presented. Mean age was 72 + 12 years, and 39.8% were female. Hospital admission was due to new-onset heart failure (HF) in 43% of cases. Comorbid conditions were observed more frequently in the worsening HF group, while those with de novo HF showed a higher heart rate, blood pressure, and more preserved left ventricular ejection fraction (LVEF). Electrical devices were previously implanted in 13.3% of the entire group. Inotropes were administered in 19.4% of the patients. The median duration of hospital stay was 10 days (interquartile range 7-15). All-cause in-hospital death was 6.4%, similar in worsening and de novo HF. Older age, hypotension, cardiogenic shock, pulmonary oedema, symptoms of hypoperfusion, hyponatraemia, and elevated creatinine were independent predictors of all-cause death.
ConclusionOur registry confirms that in-hospital mortality in AHF is still high, with a long length of stay. Pharmacological treatment seems to be practically unchanged in the last decades, and the adherence to HF guidelines concerning implantable cardioverter defibrillators/cardiac resynchronization therapy is still very low. Some AHF phenotypes are characterized by worst prognosis and need specific research projects.--
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.