Background and Aims Patients undergoing hemodialysis (HD) through a tunneled central venous catheter are exposed to several risks. Catheter-related bloodstream infection (CR-BSI) is the second major cause of death in this population. To reduce the incidence of CR-BSI we conducted a non-randomized pre-post intervention study aimed to eliminate all preventable CR-BSI. Method A quasi-experimental study was conducted in an intra-hospital hemodialysis unit with 15 HD machines and attending 70 patients until March 2019, and 24 machines and 90 patients from that date until today. The CDC, CR-BSI criteria for dialysis event surveillance protocol, defined as the presence of a positive blood culture with the suspect source report as the vascular access or uncertain was used to define CR-BSI. A sequential implementation of evidence-based interventions, associated in literature with the reduction of CR-BSI rate, were developed between January 2011 and January 2020. The intervention package included: 1. Alcohol based gel delivery system fixed in every HD machine to enhance hand hygiene adherence 2. A new strict aseptic protocol for connecting/disconnecting HD lines that included: 2.1 Wrapping catheter rubs for 1-2 minutes with alcoholic chlorhexidine-saturated gauze before removal catheters caps 2.2 Nurses and patients wear masks during catheter manipulation 2.3 Apply a sterile fenestrate drape with sterile gloves before removing the caps 2.4 The scrub-the-hub aseptic technic after removing the caps with alcoholic chlorhexidine-saturated gauze 2.5 Precocious use of Tissue Plasminogen Activator (rTPA) to correct inadequate blood flow, avoiding excess of catheter manipulation 3. Use of chlorhexidine-impregnated dressing changed once a week 4. Training all nurse staff admitted, catheter care skill evaluation semiannually, re-training when necessary and monthly infection rate feedback 5. Use of citrate 30% as lock solution. Results During the follow-up period (January 2011 to January 2020) a mean of 45 patients (range 30-55) used tunneled catheter as vascular access each year. The mean age was 69±15 years (range 11-96 years), with 60% of patients been diabetic. After implementation the of the new strategies we observed a continuous reduction in the CR-BSI rate: 2010 the year before strategies implementation CR-BSI rate was 1.1/1000 catheter-days; 2011 CR-BSI rate 0.6/1000 catheter-days; 2012 CR-BSI rate 0.6/1000 catheter-days; 2013 CR-BSI rate 0.1/1000 catheter-days; 2014 CR-BSI rate 0.1/1000 catheter-days; 2015 CR-BSI rate 0.2/1000 catheter-days; 2016 CR-BSI rate 0.2/1000 catheter-days; 2017 CR-BSI rate 0.0/1000 catheter-days, 2018 CR-BSI rate 0.08/1000 catheter-days, and 2019 CR-BSI rate 0.06/1000 catheter-days. Between April 10th of 2016 and January 10th of 2020, a 1430 days period, we observed only 2 CR-BSI. Between April 10th of 2016 and January 3rd of 2018 there was a period of 633 days with no CR-BSI. Conclusion Implementation of several evidence-based practices and continuous education can reduce CR-BSI in HD patients to a very low level. Targeting zero infection proposing to eliminate all preventable infection should be the routine practice of all dialysis units.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.