IntroductionThe benefits of higher positive end expiratory pressure (PEEP) in patients with acute respiratory distress syndrome (ARDS) have been modest, but few studies have fully tested the "open-lung hypothesis". This hypothesis states that most of the collapsed lung tissue observed in ARDS can be reversed at an acceptable clinical cost, potentially resulting in better lung protection, but requiring more intensive maneuvers. The short-/middle-term efficacy of a maximum recruitment strategy (MRS) was recently described in a small physiological study. The present study extends those results, describing a case-series of non-selected patients with early, severe ARDS submitted to MRS and followed until hospital discharge or death.MethodsMRS guided by thoracic computed tomography (CT) included two parts: a recruitment phase to calculate opening pressures (incremental steps under pressure-controlled ventilation up to maximum inspiratory pressures of 60 cmH2O, at constant driving-pressures of 15 cmH2O); and a PEEP titration phase (decremental PEEP steps from 25 to 10 cmH2O) used to estimate the minimum PEEP to keep lungs open. During all steps, we calculated the size of the non-aerated (-100 to +100 HU) compartment and the recruitability of the lungs (the percent mass of collapsed tissue re-aerated from baseline to maximum PEEP).ResultsA total of 51 severe ARDS patients, with a mean age of 50.7 years (84% primary ARDS) was studied. The opening plateau-pressure was 59.6 (± 5.9 cmH2O), and the mean PEEP titrated after MRS was 24.6 (± 2.9 cmH2O). Mean PaO2/FiO2 ratio increased from 125 (± 43) to 300 (± 103; P < 0.0001) after MRS and was sustained above 300 throughout seven days. Non-aerated parenchyma decreased significantly from 53.6% (interquartile range (IQR): 42.5 to 62.4) to 12.7% (IQR: 4.9 to 24.2) (P < 0.0001) after MRS. The potentially recruitable lung was estimated at 45% (IQR: 25 to 53). We did not observe major barotrauma or significant clinical complications associated with the maneuver.ConclusionsMRS could efficiently reverse hypoxemia and most of the collapsed lung tissue during the course of ARDS, compatible with a high lung recruitability in non-selected patients with early, severe ARDS. This strategy should be tested in a prospective randomized clinical trial.
OBJECTIVE:To determine morbidity and mortality rates by risk category in accordance with the American College of Chest Physicians guidelines, to determine what role pulmonary function tests play in this categorization process, and to identify risk factors for perioperative complications (PCs).METHODS:This was a historical cohort study based on preoperative and postoperative data collected for cases of lung cancer diagnosed or suspected between 2001 and 2010. RESULTS:Of the 239 patients evaluated, only 13 (5.4%) were classified as being at high risk of PCs. Predicted postoperative FEV1 (FEV1ppo) was sufficient to define the risk level in 156 patients (65.3%); however, cardiopulmonary exercise testing (CPET) was necessary for identifying those at high risk. Lung resection was performed in 145 patients. Overall morbidity and mortality rates were similar to those reported in other studies. However, morbidity and mortality rates for patients at an acceptable risk of PCs were 31.6% and 4.3%, respectively, whereas those for patients at high risk were 83.3% and 33.3%. Advanced age, COPD, lobe resection, and lower FEV1ppo were correlated with PCs.CONCLUSIONS:Although spirometry was sufficient for risk assessment in the majority of the population studied, CPET played a key role in the identification of high-risk patients, among whom the mortality rate was seven times higher than was that observed for those at an acceptable risk of PCs. The risk factors related to PCs coincided with those reported in previous studies.
OBJETIVO: Comparar a incidência de complicações pulmonares e cardiopulmonares estimadas, respectivamente, pelas escalas de Torrington e Henderson e de Epstein, em amostra populacional submetida à ressecção pulmonar para tratamento de câncer de pulmão. MÉTODOS: Dados de doentes submetidos à ressecção de um lobo pulmonar ou mais foram retirados de dois bancos de dados montados de forma prospectiva, oriundos de dois hospitais terciários. As medidas de desfecho analisadas foram complicações pulmonares, cardíacas e óbito. Teste exato de Fisher foi usado para avaliar a concordância das taxas de complicações obtidas com as estimadas previamente. RESULTADOS: A escala de Torrington e Henderson foi aplicada em 50 doentes (12 apresentaram risco leve, 32 moderado e 6 grave) e subestimou a taxa de complicações pulmonares nas categorias leve e moderado (p = 0,0003 e p = 0,0006, respectivamente), porém foi capaz de reconhecer os pacientes com alto risco de desenvolver complicações. A escala de Epstein foi aplicada em 38 doentes (4 apresentaram risco alto e 34 baixo) e também subestimou a taxa de complicações cardiopulmonares pós-operatórias da categoria de risco leve, que continha a maioria dos doentes (p < 0,0001), mas reconheceu, também, os pacientes com chance alta de complicar. CONCLUSÃO: As duas escalas não foram adequadas para estimar ocorrência de complicações pulmonares e cardiopulmonares na maioria dos doentes.
Objectives To characterize an experimental model of pulmonary embolism by studying hemodynamics, lung mechanics and histopathologic derangements caused by pulmonary microembolism in pigs. To identify lung alterations after embolism that may be similar to those evidenced in pulmonary inflammatory conditions. Materials and methods Ten Large White pigs (weight 35-42 kg) were instrumented with arterial and pulmonary catheters, and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter ~300 µM), in order to obtain a pulmonary mean arterial pressure of twice the baseline value. Five other animals injected with saline served as controls. Hemodynamic and respiratory data were collected and pressure x volume curves of the respiratory system were performed by a quasi-static low flow method. Animals were followed for 12 hours, and after death lung fragments were dissected and sent to pathology. Results Pulmonary embolism induced a significant reduction in stroke volume (71 ± 18 ml/min/bpm pre vs 36 ± 9 ml/min/bpm post, P < 0.05), an increase in pulmonary mean arterial pressure (27 ± 4 mmHg pre vs 39 ± 6 mmHg post, P < 0.05) and pulmonary vascular resistance (193 ± 122 mmHg/l/min pre vs 451 ± 149 mmHg/l/min post, P < 0.05). Respiratory dysfunction was evidenced by significant reductions in the PaO 2 /FiO 2 ratio (480 ± 50 pre vs 159 ± 55 post, P < 0.05), the dynamic lung compliance (27 ± 6 ml/cmH 2 O pre vs 19 ± 5 ml/cmH 2 O post, P < 0.05), the increase in dead space ventilation (20 ± 4 pre vs 47 ± 20 post, P < 0.05) and, the shift of pressure x volume curves to the right, with reduction in pulmonary hysteresis. Pathology depicted inflammatory neutrophil infiltrates, alveolar edema, collapse and hemorrhagic infarctions. Conclusion This model of embolism is associated with cardiovascular dysfunction, as well as respiratory injury characterized by a decrease in oxygenation, lung compliance and hysteresis. Pathology findings were similar to those verified in inflammatory pulmonary injury conditions. This model may be useful to study pathophysiology, as well as pharmacologic and ventilatory interventions useful to treat pulmonary embolism. P6 Hemodynamic and metabolic features of a porcine systemic low flow state model
Introduction Cardiac surgery with cardiopulmonary bypass (CPB) is a recognized trigger of systemic inflammatory response, usually related to postoperative acute lung injury (ALI). As an attempt to dampen inflammatory response, steroids have been perioperatively administered to patients. Macrophage migration inhibitory factor (MIF), a regulator of the endotoxin receptor, is implicated in the pathogenesis of ALI. We have previously detected peak circulating levels of MIF, 6 hours post CPB. Experimental data have shown that steroids may induce MIF secretion by mononuclear cells. This study aims to correlate levels of MIF assayed 6 hours post CPB to the intensity of postoperative pulmonary dysfunction, analysing the impact of perioperative steroid administration. MethodsWe included patients submitted to cardiac surgery with CPB, electively started in the morning, performed by the same team under a standard technique except for the addition of methylprednisolone (15 mg/kg) to the CPB priming solution for patients from group MP (n = 37), but not for the remaining patients -group NS (n = 37). MIF circulating levels were assayed at the anesthesia induction, 3, 6, and 24 hours after CPB. A standard weaning protocol with fast track strategy was adopted, and indicators of organ dysfunction and therapeutic intervention were registered during the first 72 hours postoperative.Results Levels of MIF assayed 6 hours post CPB correlated directly to the postoperative duration of mechanical ventilation (P = 0.014, rho = 0.282) and inversely to PaO 2 /FiO 2 ratio (P = 0.0021, rho = -0.265). No difference in MIF levels was noted between the groups. The duration of mechanical ventilation was higher (P = 0.005) in the group MP (7.92 ± 6.0 hours), compared with the group NS (4.92 ± 3.6 hours). ConclusionCirculating levels of MIF assayed 6 hours post CPB are correlated to postoperative pulmonary performance. Immunosuppressive doses of methylprednisolone did not affect circulating levels of MIF and may be related to prolonged mechanical ventilation. P2Immediate and short-term safety of catheter-based autologous bone marrow-derived mononuclear cell transplantation into myocardium of patients with severe ischemic heart failure Background Bone marrow-derived mononuclear cell (BM-MNC) transplantation into the myocardium has been proposed as a new therapy for ischemic heart failure (HF). Successful cellular therapy for HF using myoblast transplantation has been reported previously but malignant arrhythmias (MA) were an issue. We investigated the safety of BM-MNC transplantation into the myocardium for MA.Methods A prospective study to evaluate the safety of autologous BM-MNC transplantation in patients with severe ischemic HF not amenable to myocardial revascularization was conducted. Bone marrow was harvested from the iliac crest and BM-MNCs were selected by Ficoll gradient. Hibernating myocardium areas were targeted using electromechanical mapping in catheter-based subendocardial injections (MyoStar, Cordis, Miami Lakes, FL, USA). All patien...
Introduction Noninvasive ventilation is a safe and eff ective method to treat acute respiratory failure, minimizing the respiratory workload and oxygenation. Few studies compare the effi cacy of diff erent types of noninvasive ventilation interfaces and their adaptation. Objective To identify the most frequently noninvasive ventilation interfaces used and eventual problems related to their adaptation in critically ill patients. Methods We conducted an observational study, with patients older than 18 years old admitted to the intensive care and step-down units of the Albert Einstein Jewish Hospital that used noninvasive ventilation. We collected data such as reason to use noninvasive ventilation, interface used, scheme of noninvasive ventilation used (continuously, periods or nocturnal use), adaptation, and reasons for nonadaptation. Results We evaluated 245 patients with a median age of 82 years (range of 20 to 107 years). Acute respiratory failure was the most frequent cause of noninvasive ventilation used (71.3%), followed by pulmonary expansion (10.24%), after mechanical ventilation weaning (6.14%) and sleep obstructive apnea (8.6%). The most frequently used interface was total face masks (74.7%), followed by facial masks in 24.5% of the patients, and 0.8% used performax masks. The use of noninvasive ventilation for periods (82.4%) was the most common scheme of use, with 10.6% using it continuously and 6.9% during the nocturnal period only. Interface adaptation occurred in 76% of the patients; the 24% that did not adapt had their interface changed to improve adaptation afterwards. The total face mask had 75.5% of interface adaptation, the facial mask had 80% and no adaptation occurred in patients that used the performax mask. The face format was the most frequent cause of nonadaptation in 30.5% of the patients, followed by patient's related discomfort (28.8%), air leaking (27.7%), claustrophobia (18.6%), noncollaborative patient (10.1%), patient agitation (6.7%), facial trauma or lesion (1.7%), type of mask fi xation (1.7%), and 1.7% patients with other causes. Conclusion Acute respiratory failure was the most frequent reason for noninvasive ventilation use, with the total face mask being the most frequent interface used. The most common causes of interface nonadaptation were face format, patient-related discomfort and air leaking, showing improvement of adaptation after changing the interface used. P2 Exercise training reduces oxidative damage in skeletal muscle of septic rats
Introduction Community-acquired pneumonia remains a common condition worldwide. It is associated with significant morbidity and mortality. The aim of this study was to evaluate conditions that could predict a poor outcome. Design Retrospective analyse of 69 patients admitted to the ICU from 1996 to 2003. Demographic data included age, sex and medical history. Etiologic agents, multiorgan dysfunction, nosocomial infections, SAPS II and PORT scores were recorded for each patient. For statistical analysis we used a t test, chi-square test and Mann-Whitney U test on SPSS ® . A value of P less than 0.05 was considered significant. Results Forty-seven patients were male and 22 patients were female. Mean age was 52 years. Sixty-seven percent had serious pre-morbid conditions including pulmonary disease (34.8%), cardiac problems (36.2%), diabetes (13%) and chronic liver disease (5.8%); 40.6% were smokers, drug abusers or alcohol dependents. Sixtyeight patients required invasive mechanical ventilation. The average length of ventilation was 13.5 days, median 8 days. The mean SAPS II score was 40.14 and the mean PORT score was 141. The mortality rate was 27.5% (SAPS II estimated mortality, 35%). Complications reported were ARDS (40.6%), septic shock (34.8%), acute renal failure (2.9%), cardiac arrest (8.7%) and nosocomial infeccions (46.4%). Mortality rates were higher for previous hepatic (75%) and metabolic (33%) diseases. We found a close association between crude mortality and SAPS II score (P = 0.003) and development of complications (P = 0.0028). Respiratory dysfunction (P = 0.006) and septic shock (P = 0.022) were most significantly related to mortality. No significant differences were founded regarding age, comorbidities, PORT score, etiologic agents, nosocomial infections and length of invasive mechanical ventilation. Conclusions Previous hepatic chronic disease was strictly related to higher mortality as well as isolation of MRSA. ARDS and septic shock predicted a poor outcome. SAPS II score was the best severity indicator of mortality. Objective It is known that the closed tracheal suction system (CTSS) produces less hemodynamic and gasometric deterioration than an open tracheal suction system (OTSS). Use is limited because no decrease in the incidence of ventilator-associated pneumonia (VAP) was found and also because it is more expensive. But, is daily periodic change of the CTSS necessary? The aim of this study was to analyze the incidence of VAP using a CTSS without periodic change versus an OTSS. Methods It is a prospective study of ICU patients from 1 January 2004 to 31 October 2004. Patients who required mechanical ventilation (MV) were randomized into two groups: one group was suctioned with CTSS without periodic change and another group with OTSS. An aspirate tracheal swab and a throat swab on admission and afterwards twice weekly were taken. VAP was classified based on throat flora in endogenous and exogenous samples. The statistical analysis was performed by chi-square test and Student's t test, and w...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.