Background Various diagnostic modalities are available to assess the problematic knee arthroplasty. Visualization of soft‐tissue structures in relation to the arthroplasty and bone remains difficult. Recent developments in MRI sequences could make MRI a viable addition to the diagnostic arsenal. Purpose To review the diagnostic properties of MRI, to identify certain causes of complaints that may be directly related to implant failure of total (TKA) or unicompartmental knee arthroplasty (UKA); infection, loosening and wear, instability, malalignment, arthrofibrosis, or patellofemoral problems. Study Type Systematic review. Population Twenty‐three studies were included: 16 TKA, four UKA, and three cadaveric studies. Causes of knee arthroplasty complaints analyzed were; infection (three), loosening and wear (11), malalignment (five) and instability (four). Field Strength and Sequences No field strength or sequence restrictions. Assessment PubMed, SCOPUS, and EMBASE were searched. Risk of bias was assessed using the COnsensus‐based Standards for the selection of health Measurement Instruments (COSMIN) and the QUality Assessment of Diagnostic Accuracy Studies‐2 (QUADAS‐2). Statistical Tests The results of the original research articles are stated. Results Fifteen studies assessed the reproducibility of analyzing infection, loosening and wear, and malalignment. Fourteen of 15 studies were deemed as adequate to good quality. Results showed a moderate to excellent agreement (ICC/K 0.55–0.97). Fourteen studies addressed the accuracy. For infection and loosening and wear the sensitivity and specificity estimates varied between 0.85–0.97 and 0.70–1.00, respectively. The accuracy for malalignment was excellent (r ≥ 0.81). For these studies QUADAS‐2 analysis suggested few risks of bias. A meta‐analysis was not possible due to the heterogeneity of the data. Data Conclusion This study supports that MRI can be used with overall reproducible and accurate results for diagnosing infection, loosening and wear, and malalignment after knee arthroplasty. Nonetheless, studies regarding the diagnosis of instability, arthrofibrosis or patellofemoral complaints using MRI are limited and inconclusive. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:446–458.
After pancreatoduodenectomy, complication rates are up to 40%. To predict the risk of developing postoperative pancreatic fistula or severe complications, various factors were evaluated. 110 consecutive patients undergoing pancreatoduodenectomy at our institute between January 2012 and September 2014 with complete CT scan were retrospectively identified. Pre-, per-, and postoperative patients and pathological information were gathered. The CT-scans were analysed for the diameter of the pancreatic duct, attenuation of the pancreas, and the visceral fat area. All data was statistically analysed for predicting POPF and severe complications by univariate and multivariate logistic regression analyses. The POPF rate was 18%. The VFA measured at umbilicus (OR 1.01; 95% CI = 1.00–1.02; P = 0.011) was an independent predictor for POPF. The severe complications rate was 33%. Independent predictors were BMI (OR 1.24; 95% CI = 1.10–1.42; P = 0.001), ASA class III (OR 17.10; 95% CI = 1.60–182.88; P = 0.019), and mean HU (OR 0.98; 95% CI = 0.96–1.00; P = 0.024). In conclusion, VFA measured at the umbilicus seems to be the best predictor for POPF. BMI, ASA III, and the mean HU of the pancreatic body are independent predictors for severe complications following PD.
Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.
Purpose: Low-field MRI, allowing imaging in supine and weight-bearing position, may be utilized as a non-invasive and affordable tool to differentiate between causes of dissatisfaction after TKA ('problematic TKA'). However, it remains unclear whether low-field MRI results in sufficient image quality with limited metal artefacts. Therefore, this feasibility study explored the diagnostic value of low-field MRI concerning pathologies associated with problematic TKA's' by comparing low-field MRI findings with CT and surgical findings. Secondly, differences in patellofemoral parameters between supine and weight-bearing low-field MRI were evaluated. Methods: Eight patients with a problematic TKA were scanned using low-field MRI in weight-bearing and supine conditions. Six of these patients underwent revision surgery. Scans were analysed by a radiologist for pathologies associated with a problematic TKA. Additional patellofemoral and alignment parameters were measured by an imaging expert. MRI observations were compared to those obtained with CT, the diagnosis based on the clinical work-up, and findings during revision surgery. Results: MRI observations of rotational malalignment, component loosening and patellofemoral arthrosis were comparable with the clinical diagnosis (six out of eight) and were confirmed during surgery (four out of six). All MRI observations were in line with CT findings (seven out of seven). Clinical diagnosis and surgical findings of collateral excessive laxity could not be confirmed with MRI (two out of eight). Conclusion: Low-field MRI shows comparable diagnostic value as CT and might be a future low cost and ionizing radiation free alternative. Differences between supine and weight-bearing MRI did not yield clinically relevant information. The study was approved by the Medical Research Ethics Committees of Twente (Netherlands Trial Register: Trial NL7009 (NTR7207). Registered 5 March 2018, https://www.trialregister.nl/trial/7009).
BackgroundRoentgen stereophotogrammetric analysis (RSA) is used to measure early prosthetic migration and to predict future implant failure. RSA has several disadvantages, such as the need for perioperatively inserted tantalum markers. Therefore, this study evaluates low-field MRI as an alternative to RSA. The use of traditional MRI with prostheses induces disturbing metal artifacts which are reduced by low-field MRI. The purpose of this study is to assess the feasibility to use low-field (0.25 Tesla) MRI for measuring the precision of zero motion. This was assessed by calculating the virtual prosthetic motion of a zero-motion prosthetic reconstruction in multiple scanning sessions. Furthermore, the effects of different registration methods on these virtual motions were tested.ResultsThe precision of zero motion for low-field MRI was between 0.584 mm and 1.974 mm for translation and 0.884° and 3.774° for rotation. The manual registration method seemed most accurate, with μ ≤ 0.13 mm (σ ≤ 0.931 mm) for translation and μ ≤ 0.15° (σ ≤ 1.63°) for rotation.ConclusionLow-field MRI is not yet as precise as today’s golden standard (marker based RSA) as reported in the literature. However, low-field MRI is feasible of measuring the relative position of bone and implant with comparable precision as obtained with marker-free RSA techniques. Of the three registration methods tested, manual registration was most accurate. Before starting clinical validation further research is necessary and should focus on improving scan sequences and registration algorithms.
Purpose To compare the accuracy, inter- and intrarater reliability, and user-experience of manual and semi-automatic preoperative leg-alignment measurement planning software for high tibial osteotomy (HTO). Methods Thirty patients (31 lower limbs) who underwent a medial opening wedge HTO between 2017 and 2019 were retrospectively included. The mechanical lateral distal femur angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and planned correction angle were measured on preoperative long-leg full weight-bearing radiographs utilising PACS Jivex Review® v5.2 manual and TraumaCad® v2.4 semi-automatic planning software. Independent measurements were performed by four raters. Two raters repeated the measurements. Accuracy in the standard error of measurement (SEM), inter- and intrarater reliability, and user-experience were analysed. Additionally, measurements errors of more than 3° were remeasured and reanalysed. Results The SEMs of all measured varus malalignment angles and planned correction angle were within 0.8° of accuracy for both software programs. Measurements utilising the manual software demonstrated moderate interrater intraclass correlation coefficient (ICC)-values for the mLDFA and mMPTA, and an excellent interrater ICC-value for the correction angle (0.810, 0.779, and 0.981, respectively). Measurements utilising the semi-automatic software indicated excellent interrater ICC-values for the mLDFA, mMPTA, and correction angle (0.980, 0.909, and 0.989, respectively). The intrarater reliability varied substantially per angle, presenting excellent intrarater agreements by both raters (ICC > 0.900) for the correction angle in each software program as well as poor-to-excellent ICC-values for the mLDFA (0.282–0.951 and 0.316–0.926) and mMPTA (0.893–0.934 and 0.594–0.941) in both the manual planning and semi-automatic software. Regarding user-experience, semi-automatic software was preferred by two raters, while the other two raters had no distinctive preference. After remeasurement of five outliers, excellent interrater ICC-values were found for the mLDFA (0.913) and mMPTA (0.957). Conclusions Semi-automatic software outperforms the manual software when user-experience and outliers are considered. However, both software programs provide similar performance after remeasurement of the human-related erroneous outliers. For clinical practice, both programs can be utilised for HTO planning. Level of evidence Diagnostic study, Level III.
We present a case report of a 12-year old female with a midshaft forearm fracture. Initial conservative treatment with a cast failed, resulting in a malunion. The malunion resulted in functional impairment for which surgery was indicated. A corrective osteotomy was planned using 3D analyses of the preoperative CT-scan. Subsequently, patient-specific guides were printed and used during the procedure to precisely correct the malunion. Three months after surgery, the radiographs showed full consolidation and the patient was pain-free with full range of motion and comparable strength in both forearms. The current case report shows that a corrective osteotomy with patient-specific guides based on preoperative 3D analyses can help surgeons to plan and precisely correct complex malunions resulting in improved functional outcomes.
of this thesis may be reproduced, stored in a retrieval system or transmitted in any form or by any means without permission of the author. Alle rechten voorbehouden. Niets uit deze uitgave mag worden vermenigvuldigd, in enige vorm of op enige wijze, zonder voorafgaande schriftelijke toestemming van de auteur.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.