The Glittre ADL-test (TGlittre) has been designed and validated to measure functional capacity during daily living activities in patients with chronic obstructive pulmonary disease (COPD) but is now used in several other situations. The aim of this study was to evaluate the applicability of TGlittre in a sample of overweight and obese eutrophic elderly. This was an experimental and cross-sectional study, which included 21 elderly women, allocated by BMI, in eutrophic (n = 8), overweight (n = 6) and obese (n = 7) groups. They were assessed for functional capacity (TGlittre and 6MWT), quality of life (QOL) with the questionnaire World Health Organization Quality of Life for Older People (WHOQOL-OLD) and handgrip strength (HGS). TGlittre correlated with age (p = 0.0040) and with 6MWT (p = 0.0086), but no statistical difference was found in TGlittre's performance time and the distance covered in 6MWT between groups. TGlittre did not correlate with HGS (p = 0.1493) and WHOQOL-Old (p = 0.0905). The data obtained in the present study corroborate that TGlittre is used as a functional measurement variable in the elderly population.Keywords: aged, obesity, exercise intolerance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.