Background Radiomics is expected to improve the management of metastatic colorectal cancer (CRC). We aimed at evaluating the impact of liver lesion contouring as a source of variability on radiomic features (RFs). Methods After Ethics Committee approval, 70 liver metastases in 17 CRC patients were segmented on contrast-enhanced computed tomography scans by two residents and checked by experienced radiologists. RFs from grey level co-occurrence and run length matrices were extracted from three-dimensional (3D) regions of interest (ROIs) and the largest two-dimensional (2D) ROIs. Inter-reader variability was evaluated with Dice coefficient and Hausdorff distance, whilst its impact on RFs was assessed using mean relative change (MRC) and intraclass correlation coefficient (ICC). For the main lesion of each patient, one reader also segmented a circular ROI on the same image used for the 2D ROI. Results The best inter-reader contouring agreement was observed for 2D ROIs according to both Dice coefficient (median 0.85, interquartile range 0.78–0.89) and Hausdorff distance (0.21 mm, 0.14–0.31 mm). Comparing RF values, MRC ranged 0–752% for 2D and 0–1567% for 3D. For 24/32 RFs (75%), MRC was lower for 2D than for 3D. An ICC > 0.90 was observed for more RFs for 2D (53%) than for 3D (34%). Only 2/32 RFs (6%) showed a variability between 2D and circular ROIs higher than inter-reader variability. Conclusions A 2D contouring approach may help mitigate overall inter-reader variability, albeit stable RFs can be extracted from both 3D and 2D segmentations of CRC liver metastases.
The aim of this multicentric study is an inter-center benchmarking, to assess how different set tools applied to the same radiomics workflow affected the radiomics features (RFs) values. This topic is of key importance to start collaboration between different centers and to bring radiomic studies from benchmark to bedside. A per-lesion analysis was performed on 56 metastases (mts) selected from 14 patients. A single radiologist performed the segmentation of all mts, and RFs were extracted from the same segmentation of each mts, using two different software and file formats. Potential sources of discrepancies were evaluated. The intraclass correlation coefficient was used to describe how strongly the same radiomic measurements calculated in the two different centers resemble each other. Moreover, means of the relative changes of each RF were calculated, compared and gradually reduced. We showed that, after matching all formulas, discrepancies in RFs calculation between two centers ranged from 1% to 277%. Therefore, we evaluated other sources of variability using a stepwise approach, which led us to reduce the inter-center discrepancies to 0% for 22/25 RFs and below 2% for 3 RFs out of 25. In this study we demonstrated that different radiomic applications and masks formats might strongly impact the computation of some RFs. Therefore, when dealing with multi-center studies it is mandatory to adopt all strategies that can help in limiting the differences, thus keeping in mind the feasibility of these strategies in large cohort studies.
Magnetic resonance imaging (MRI) is a non-invasive powerful modern clinical technique that is extensively used for the high-resolution imaging of soft tissues. To obtain high-definition pictures of tissues or of the whole organism this technique is enhanced by the use of contrast agents. Gadolinium-based contrast agents have an excellent safety profile. However, over the last two decades, some specific concerns have surfaced. Mn(II) has different favorable physicochemical characteristics and a good toxicity profile, which makes it a good alternative to the Gd(III)-based MRI contrast agents currently used in clinics. Mn(II)-disubstituted symmetrical complexes containing dithiocarbamates ligands were prepared under a nitrogen atmosphere. The magnetic measurements on Mn complexes were carried out with MRI phantom measurements at 1.5 T with a clinical magnetic resonance. Relaxivity values, contrast, and stability were evaluated by appropriate sequences. Studies conducted to evaluate the properties of paramagnetic imaging in water using a clinical magnetic resonance showed that the contrast, produced by the complex [Mn(II)(L’)2] × 2H2O (L’ = 1.4-dioxa-8-azaspiro[4.5]decane-8-carbodithioate), is comparable to that produced by gadolinium complexes currently used in medicine as a paramagnetic contrast agent.
Background: To manage and analyse dosimetric data provided by computed tomography (CT) scanners from four Italian hospitals. Methods: A radiation dose index monitoring (RDIM) software was used to collect anonymised exams stored in a cloud server. Since hospitals use different names for the same procedure, digital imaging and communications in medicine (DICOM) tags more appropriate to describe exams were selected and associated to study common names (SCNs) from a radiology playbook according to scan region and use of contrast media. Retrospective analysis was carried out to describe population and to evaluate dosimetric indexes and inaccuracies associated with SCNs. Results: More than 400 procedures were clustered into 95 SCNs, but 78% of exams on adults were described with only 10 SCNs. Median values of dose-length product (DLP) and volumetric CT dose index (CTDI vol) for three analysed SCNs were in agreement with those previously published. The percentage of inaccuracies does not heavily affect the dosimetric analysis on the whole cloud, since variations in median values reached at most 8%. Conclusions: Implementation of a cloud-based RDIM software and related issues were described, showing the strength of the chosen playbook-based clustering and its usefulness for homogeneous data analysis. This approach may allow for optimisation actions, accurate assessment of the risk associated with radiation exposure, comparison of different facilities, and, last but not least, collection of information for the implementation of the 2013/59 Euratom Directive.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.