A dual gated tomography (DGT) program for end systolic and end diastolic acquisition and subsequent processing for calculation of LVEF, end diastolic and end systolic volumes (EDV, ESV) has been evaluated in 20 healthy volunteers (25 years-40 years) and 45 patients (25 years-60 years): 20 with ischaemic heart disease and 25 with valvular heart disease (VHD). All had biplane multigated blood pool (MUGA) studies in the 40 degrees LAO projection using in vivo 99mTc- RBCs, immediately followed by DGT. The results in the patients group were correlated with contrast ventriculography (CV). In the volunteer group, the normal values for LVEF, EDV and ESV measured with DGT were found to be 63% +/- 10%, 91 ml +/- 6 ml and 30 ml +/- 6 ml and r value for the LVEF = 0.91 compared with MUGA. In the IHD group, r values compared with CV were 0.915 and 0.97 for the EDV and ESV and 0.934 for the LVEF. Compared with the MUGA, the r value for LVEF was 0.883. In the VHD group, r values were 0.98 for both the EDV and ESV and 0.948 for the LVEF (P less than 0.002) compared with CV and 0.789 for the LVEF compared with the MUGA. We feel that DGT is an accurate and reproducible technique for LV function measurements.
Intravenously injected 99mTc-DTPA was evaluated in 64 patients for its efficiency in detecting and localizing sites of acute upper and lower gastrointestinal (G.I.) bleeding. These studies were correlated with endoscopic and surgical findings. There were 34 bleeders and 30 non bleeders giving a sensitivity of 90%, specificity of 82% and accuracy of 86%. Of these, 49 were upper G.I. studies (stomach 21 and duodenum 28) and 15 were lower G.I. studies (small intestine 8, large bowel 7). Of the 49 upper G.I. studies, 27 showed active bleeding while 22 showed no bleeding at the time of the study resulting in a sensitivity of 87.5%, specificity of 76% and accuracy of 82%. Of the 15 lower G.I. studies, 7 were bleeders while 8 were non bleeders. All the lower G.I. bleeding sites were accurately localized with the 99mTc-DTPA. An incidental finding of these studies was the localization of 99mTc-DTPA in the site of inflammatory and malignant lesions of the G.I. tract. Of the 64 studies, 18 inflammatory and malignant lesions were detected with the IV injected 99mTc-DTPA; 10 were bleeders while 8 were non bleeders. Image subtraction of early from delayed images was helpful to differentiate bleeding from non bleeding cases in this last group of studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.